Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparative analysis of indoor thermal comfort in a residential building by applying dynamic clothing insulation

Authors
Choi, Eun JiCho, Hye UnHyun, Ji YeonPark, Jin ChulMoon, Jin Woo
Issue Date
2021
Publisher
Architectural Institute of Korea
Keywords
Clothing Insulation; Indoor Environment; Predicted Mean Vote; Predicted Percentage Dissatisfied; Thermal Comfort
Citation
Journal of the Architectural Institute of Korea, v.37, no.4, pp 205 - 212
Pages
8
Journal Title
Journal of the Architectural Institute of Korea
Volume
37
Number
4
Start Page
205
End Page
212
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/52278
DOI
10.5659/JAIK.2021.37.4.205
ISSN
2733-6239
2733-6247
Abstract
The purpose of this study is to confirm the necessity and significance of applying a dynamic clothing insulation for controlling the thermal environment. For this purpose, the comparative analysis of indoor thermal comfort in the residential building was conducted with three different control methods: 1) DBT (dry-bulb temperature)-based control, 2) PMV (predicted mean vote)-based controls reflecting the fixed clothing insulation, 3) PMV-based control reflecting the dynamic clothing insulation. DesignBuilder was employed for a residential building modeling and the thermal comfort analysis which was accessed with PMV and PPD (predicted percentage dissatisfied) indicators. As a result, the PMV-based control applying the dynamic clothing insulation satisfied the comfort ranges of the PMV and PPD at all times regardless of the season. On the other hand, in the case of the DBT-based control, the average PMV value was out of the comfort range in both seasons, and the PPD value was more than twice that of the PMV-based control reflecting the dynamic clothing insulation. In addition, PMV-based control reflecting fixed clothing insulation resulted in a slightly cold condition in the morning and at night in both seasons as presenting PMV values below –0.5 and PPD values over 10%. In conclusion, from this study, the possibility was confirmed that the PMV-based control reflecting dynamic clothing insulation can provide a comfortable thermal environment for the occupants. Therefore, it is necessary to apply the accurate value of the clothing insulation in order to comfortably control the thermal environment, and a follow-up research should be conducted to develop a prediction model of the real-time clothing insulation. © 2021 Architectural Institute of Korea.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Moon, Jin Woo photo

Moon, Jin Woo
공과대학 (건축학)
Read more

Altmetrics

Total Views & Downloads

BROWSE