Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Feedforward plus feedback control of an electro-hydraulic valve system using a proportional control valve

Full metadata record
DC Field Value Language
dc.contributor.authorKo, Y.-R.-
dc.contributor.authorKim, T.-H.-
dc.date.accessioned2022-01-12T05:43:06Z-
dc.date.available2022-01-12T05:43:06Z-
dc.date.issued2020-06-
dc.identifier.issn2076-0825-
dc.identifier.issn2076-0825-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/53366-
dc.description.abstractThe output feedback signal of the electro-hydraulic valve system (EHVS) affects the activation of its right or left envelope function; thus, even weak measurement noise can cause high-frequency switching between the two envelope functions, leading to chattering in the control input. Consequently, feedforward and feedback controllers in a cascaded configuration generate undesirable chattering in the output signal. We propose a practical and reliable control approach for an EHVS actuated by a proportional control valve. The proposed controller has a parallel structure comprising an inverse generalized Prandtl-Ishlinskii (P-I) model-based feedforward controller, with both hydraulic dead-zone and flow saturation limits, for compensating asymmetric hysteretic behavior. Further, the proposed controller comprises a robust proportional-integral-derivative (PID) feedback controller for achieving robustness against disturbances and noises. The proposed parallel structure is independent of the output feedback of the EHVS. Moreover, the proposed robust PID feedback controller guarantees EHVS stability by precisely selecting the cutoff frequency for the sensitivity and complementary sensitivity functions based on the amplitude spectrum of the inverse-model-based feedforward compensation error. The results verify the high reliability of the proposed EHVS control scheme for the precise control of an EHVS actuated by a proportional control valve in practice. © 2020 by the authors.-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI AG-
dc.titleFeedforward plus feedback control of an electro-hydraulic valve system using a proportional control valve-
dc.typeArticle-
dc.identifier.doi10.3390/ACT9020045-
dc.identifier.bibliographicCitationActuators, v.9, no.2-
dc.description.isOpenAccessN-
dc.identifier.wosid000551235200019-
dc.identifier.scopusid2-s2.0-85087501103-
dc.citation.number2-
dc.citation.titleActuators-
dc.citation.volume9-
dc.type.docTypeArticle-
dc.publisher.location스위스-
dc.subject.keywordAuthorAsymmetric hysteresis-
dc.subject.keywordAuthorElectro-hydraulic valve system-
dc.subject.keywordAuthorInverse generalized prandtl-ishlinskii model-
dc.subject.keywordAuthorProportional control valve-
dc.subject.keywordAuthorRobust proportional-integral-derivative control-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryEngineering, Mechanical-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Tae Hyoung photo

Kim, Tae Hyoung
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE