Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Poor outcomes of primary total knee arthroplasty in patients with Parkinson's disease

Authors
Baek, Ji-HoonNam, Chang HyunLee, Su ChanAhn, Hye SunHa, Yong-Chan
Issue Date
Mar-2021
Publisher
SPRINGER
Keywords
Total knee arthroplasty; Parkinson’ s disease; Outcomes; Mortality
Citation
INTERNATIONAL ORTHOPAEDICS, v.45, no.3, pp 643 - 647
Pages
5
Journal Title
INTERNATIONAL ORTHOPAEDICS
Volume
45
Number
3
Start Page
643
End Page
647
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/54072
DOI
10.1007/s00264-020-04924-z
ISSN
0341-2695
1432-5195
Abstract
Purpose The purpose of this study was to compare the functional outcomes, activity levels, mortalities, implant survival rates, and complications of total knee arthroplasty (TKA) of patients with Parkinson's disease (PD) with those of patients in a control group over a minimum ten year follow-up period. Methods From January 2007 to December 2009, 46 TKAs were performed in 29 patients with PD (PD group). Fifty-eight matched patients without PD were used as the control group in a two-to-one ratio using propensity scoring matching. The functional outcomes, activity levels, mortalities, implant survival rates, and complications of TKA in patients with PD and control group were compared. Results The mean Knee Society knee scores in PD and control group improved from 36.8 and 37.1 pre-operatively to 60.0 and 80.7 points at the final follow-up, respectively (p < 0.05). Outdoor ambulatory patients at the final follow-up included 13 of 20 (65.0 %) in PD group and 51 of 54 (94.4%) patients in control group (p < 0.05). The cumulative mortality rates in PD and control group were 31% (9/29) and 6.9% (4/58) (p < 0.05), at final follow-up, respectively. Kaplan-Meier survivorship analysis with revision of either components as endpoints in PD and control group estimated 89.7% and 98.3% chances of survival for ten years, respectively. Conclusions TKAs in patients with PD were shown to have worse functional outcomes and higher mortality over a minimum ten year follow-up period. Therefore, the necessity of the procedure should be considered carefully depending on patient needs and conditions.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE