Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Bacteria adsorption on hydrophilic surfaces for the sensitive detection of pathogenic bacteria using a single tube chamber system

Authors
Won, Ji YeongMin, JunhongPark, Jung-Hwan
Issue Date
Dec-2010
Publisher
ELSEVIER ADVANCED TECHNOLOGY
Keywords
Bacteria adsorption; NSABA; Escherichia coli O157:H7; Bacillus cereus; Divalent ions
Citation
BIOSENSORS & BIOELECTRONICS, v.26, no.4, pp 1763 - 1767
Pages
5
Journal Title
BIOSENSORS & BIOELECTRONICS
Volume
26
Number
4
Start Page
1763
End Page
1767
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/55842
DOI
10.1016/j.bios.2010.08.037
ISSN
0956-5663
1873-4235
Abstract
Here, we developed a simple and effective bacterial isolation method that can be directly used for the detection of pathogenic bacteria. This approach only requires a single plastic tube chamber that can performing serial processes such as cell gathering, cell lysis, nucleic acid amplification, and signaling without the need to transfer samples from one chamber to another. A TEOS (tetraethoxysilane) surface was selected for this application because of its superior performance in the amplification process as well as the ability of bacteria to adsorb to its surface, which is necessary for all processes to be performed in single chamber. The optimal aquatic buffer conditions for bacteria adsorption on the hydrophilic surface were determined to be 1% polyethylene glycerol (PEG) and 10 mM MgCl2 in 100 mM phosphate at pH 4 for the gram negative bacteria. Escherichia coli O157:H7 (E. coli O157:H7) and 10 mM Na2SO4 in 100 mM phosphate in 100 mM phosphate at pH 4 for the gram positive bacteria, Bacillus cereus (B. cereus). When these divalent cation and anion (MgSO4) containing acidic solutions were used, 40% of both bacteria adsorbed onto the hydrophilic surface at a loading rate of 2 mL/min after introduction of low concentrations of bacteria. This method was directly employed to detect E. coli O157:H7 in beef using a single plastic tube chamber that was partially filled with nickel micro beads coated with TEOS. In this system, E. coli O157:H7 were lysed by induction heating of the nickel micro beads. The extracted mRNA was readily amplified and detected by adding an isothermal amplification mixture (NASBA, nucleic acid sequence based amplification) containing a hair-loop type reporting probe with FAM and DABCYL. As a result, this highly sensitive sensing tool could detect very low concentrations of E. coli [10(0) CFU/1 g of beef]. (C) 2010 Elsevier B.V. All rights reserved.
Files in This Item
Appears in
Collections
College of ICT Engineering > School of Integrative Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Min, Junhong photo

Min, Junhong
창의ICT공과대학 (융합공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE