Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Deep learning image reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of image quality and radiation dose in a phantom study

Authors
Park, Hye JooChoi, Seo-YounLee, Ji EunLim, SanghyeokLee, Min HeeYi, Boem HaCha, Jang GyuMin, Ji HyeLee, BoraJung, Yunsub
Issue Date
Jun-2022
Publisher
SPRINGER
Keywords
Multidetector computed tomography; Image reconstruction; Artificial intelligence
Citation
EUROPEAN RADIOLOGY, v.32, no.6, pp 3974 - 3984
Pages
11
Journal Title
EUROPEAN RADIOLOGY
Volume
32
Number
6
Start Page
3974
End Page
3984
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/61771
DOI
10.1007/s00330-021-08459-8
ISSN
0938-7994
1432-1084
Abstract
Objectives To compare the image quality and radiation dose of a deep learning image reconstruction (DLIR) algorithm compared with iterative reconstruction (IR) and filtered back projection (FBP) at different tube voltages and tube currents. Materials and methods A customized body phantom was scanned at different tube voltages (120, 100, and 80 kVp) with different tube currents (200, 100, and 60 mA). The CT datasets were reconstructed with FBP, hybrid IR (30% and 50%), and DLIR (low, medium, and high levels). The reference image was set as an image taken with FBP at 120 kVp/200 mA. The image noise, contrast-to-noise ratio (CNR), sharpness, artifacts, and overall image quality were assessed in each scan both qualitatively and quantitatively. The radiation dose was also evaluated with the volume CT dose index (CTDIvol) for each dose scan. Results In qualitative and quantitative analyses, compared with reference images, low-dose CT with DLIR significantly reduced the noise and artifacts and improved the overall image quality, even with decreased sharpness (p < 0.05). Despite the reduction of image sharpness, low-dose CT with DLIR could maintain the image quality comparable to routine-dose CT with FBP, especially when using the medium strength level. Conclusion The new DLIR algorithm reduced noise and artifacts and improved overall image quality, compared to FBP and hybrid IR. Despite reduced image sharpness in CT images of DLIR algorithms, low-dose CT with DLIR seems to have an overall greater potential for dose optimization.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Business & Economics > Department of Applied Statistics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE