Utilization of tin filters for streak artifact reduction in cone-beam computed tomographyUtilization of tin filters for streak artifact reduction in cone-beam computed tomography

Authors
Chun, M.Choi, Jin HwaKwon, O.Jin, H.Lee, S.Y.Choi, C.H.Kim, J.-I.Park, J.M.
Issue Date
May-2022
Publisher
Korean Physical Society
Keywords
Cone-beam CT; Imaging dose; Streak artifact reduction; Tin filter
Citation
Journal of the Korean Physical Society, v.80, no.10, pp 1018 - 1027
Pages
10
Journal Title
Journal of the Korean Physical Society
Volume
80
Number
10
Start Page
1018
End Page
1027
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/61907
DOI
10.1007/s40042-022-00446-6
ISSN
0374-4884
1976-8524
Abstract
This study aims streak artifacts reduction in cone-beam computed tomography (CBCT) by mounting tin filters at the Trilogy system. An anthropomorphic phantom with insertions of aluminum and titanium rods was scanned using the standard dose head (SDH) and high-quality head (HQH) CBCT protocols with no tin filters as well as 0.2 mm, 0.4 mm, and 0.6 mm thick tin filters. To quantify the degrees of streak artifacts of each CBCT image, the values of percent integrity uniformity (PIU), coefficients of fast Fourier transform (FFT), and standard deviations (SD) along the profiles at the vicinity of insertion materials were calculated. In addition, noise levels, contrast-to-noise ratio (CNR), and low contrast visibility (LCV) were analyzed by using the CBCT images of the Catphan 504 phantom, of which scanning conditions were identical to those of the anthropomorphic phantom. To evaluate imaging doses, the weighted CT dose indices and point doses measured with optically stimulated luminescence dosimeters were acquired. The PIU values of the CBCT images using the HQH protocol with a 0.4 mm-thick tin filter were always larger than those using SDH protocol without the filter which is currently used in the clinic (larger PIU indicates fewer streak artifact). The values of SD and coefficients of FFT using the HQH protocols with a 0.4 mm-thick tin filter were always smaller than those using SDH without the filter (smaller SD and FFT coefficients indicates fewer streak artifact). Although noise levels, CNR, and LCV were degraded as thicker as the tin filters, those of 0.4 mm tin filters with HQH protocol showed similar values to those of SDH protocol. By mounting 0.4 mm-thick tin filters, imaging doses were lower by 25% than those without the filter. Streak artifact can be reduced with a 0.4 mm tin filter and HQH protocol in CBCT with imaging dose reduction. © 2022, The Korean Physical Society.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Jin Hwa photo

Choi, Jin Hwa
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE