Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

New analysis methods for skin fine-structure via optical image and development of 3D skin Cycloscan (TM)

Authors
Han, J. Y.Nam, G. W.Lee, H. K.Kim, M. J.Kim, E. J.
Issue Date
Nov-2015
Publisher
WILEY
Keywords
skin fine-structure; optical image; wrinkle; pore; skin texture; 3D Skin CycloScan (TM)
Citation
SKIN RESEARCH AND TECHNOLOGY, v.21, no.4, pp 387 - 391
Pages
5
Journal Title
SKIN RESEARCH AND TECHNOLOGY
Volume
21
Number
4
Start Page
387
End Page
391
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/64438
DOI
10.1111/srt.12202
ISSN
0909-752X
1600-0846
Abstract
Background/PurposeThis study was conducted to develop methods for measuring skin fine-structure via optical image and apparatus for photographing to analyze efficacy of anti-aging. MethodsWe developed an apparatus named 3D Skin CycloScan to evaluatetheefficacyof cosmeticsby imagification of skin fine-structure such as wrinkles, pores, and skin texture. The semi-sphere shaped device has 12 different sequential flashing light sources captures optical image simultaneously in one second to exclude the influence of the subject's movement. The normal map that is extracted through shape from shading method is composed of face contour and skin fine-structure parts. When the low-frequency component which is the result of the Gaussian Filter application is eliminated, we can get only skin fine-structure. In this normal map, it is possible to extract two-dimensional vector map called direction map and we can regulate the intensity of the image of wrinkles, pores, and skin texture after filtering the direction map. We performed a clinical study to apply this new apparatus and methods to evaluate an anti-aging efficacy of cosmetics visually and validate with other conventional methods. ResultsAfter using anti-aging cream including 2% adenosine for 8weeks, the total amount of fine wrinkle around eye area detected via 3D Skin CycloScan was reduced by 12.1%. Also, wrinkles on crow's feet measured by PRIMOS COMPACT((R)) (GFMesstechnik GmbH, Germany) reduced 11.7%. ConclusionAccording to an aspect of the present study, by changing the direction of the lights toward to subject's skin, we can obtain the information about the fine structures present on the skin such as wrinkles, pores, or skin texture and represent it as an image.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE