Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Transient elastography with controlled attenuation parameter versus two-dimensional shear wave elastography with attenuation imaging for the evaluation of hepatic steatosis and fibrosis in NAFLDopen accessTransient elastography with controlled attenuation parameter versus two-dimensional shear wave elastography with attenuation imaging for the evaluation of hepatic steatosis and fibrosis in NAFLD

Authors
Seo, Jung WookKim, Youe ReeJang, Jong KeonKim, So YeonCho, Young YounLee, Eun SunLee, Dong Ho
Issue Date
Jul-2023
Publisher
KOREAN SOC ULTRASOUND MEDICINE
Keywords
Liver cirrhosis; Fatty liver; Elasticity imaging techniques
Citation
ULTRASONOGRAPHY, v.42, no.3, pp 421 - 431
Pages
11
Journal Title
ULTRASONOGRAPHY
Volume
42
Number
3
Start Page
421
End Page
431
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/68476
DOI
10.14366/usg.22212
ISSN
2288-5919
2288-5943
Abstract
Purpose: This study compared the controlled attenuation parameter (CAP) to attenuation imaging (ATI) in the diagnosis of steatosis and transient elastography (TE) to two-dimensional shear wave elastography (2D-SWE) for the diagnosis of fibrosis in a prospectively constructed nonalcoholic fatty liver disease (NAFLD) patient cohort. Methods: Participants who underwent TE with CAP were included from a previously constructed NAFLD cohort with multiparametric ultrasound data. The degree of hepatic steatosis and stage of liver fibrosis were assessed. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC) for the grades of steatosis (S1-3) and fibrosis (F0-F4).Results: There were 105 participants. The distribution of hepatic steatosis grades (S0-S3) and liver fibrosis stages (F0-F4) was as follows: S0, n=34; S1, n=41; S2, n=22; S3, n=8; F0, n=63; F1, n=25; F2, n=5; F3, n=7; and F4, n=5. No significant difference was found between CAP and ATI in detecting >_S1 (AUROC: 0.93 vs. 0.93, P=0.956) or >_S2 (0.94 vs. 0.94, P=0.769). However, the AUROC of ATI in detecting >_S3 was significantly higher than that of CAP (0.94 vs. 0.87, P=0.047). Regarding the detection of liver fibrosis, no significant difference was found between TE and 2D-SWE. The AUROCs of TE and 2D-SWE were as follows: >_F1, 0.94 vs. 0.89 (P=0.107); >_F2, 0.89 vs. 0.90 (P=0.644); >_F3, 0.91 vs. 0.90 (P=0.703); and >_F4, 0.88 vs. 0.92 (P=0.209).Conclusion: 2D-SWE and TE showed comparable diagnostic performance in assessing liver fibrosis, and ATI provided significantly better performance in detecting >_S3 steatosis than CAP.
Files in This Item
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Young Youn photo

Cho, Young Youn
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE