Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imagingopen access

Authors
Cha Min JaeAn Don-GwanKang MinsooKim Hyue MeeKim Sang-WookCho IksungHong JoonhwaChoi HyewonCho Jee-HyunShin Seung YongSong Simon
Issue Date
Jul-2023
Publisher
대한영상의학회
Keywords
Atrial fibrillation; Left atrial appendage occlusion; Hemodynamics; 4D flow MRI; Stasis; Thrombogenicity
Citation
Korean Journal of Radiology, v.24, no.7, pp 647 - 659
Pages
13
Journal Title
Korean Journal of Radiology
Volume
24
Number
7
Start Page
647
End Page
659
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/68852
DOI
10.3348/kjr.2023.0173
ISSN
1229-6929
2005-8330
Abstract
Objective: The study was conducted to investigate the effect of correct occlusion of the left atrial appendage (LAA) on intracardiac blood flow and thrombus formation in patients with atrial fibrillation (AF) using four-dimensional (4D) flow magnetic resonance imaging (MRI) and three-dimensional (3D)-printed phantoms.Materials and Methods: Three life-sized 3D-printed left atrium (LA) phantoms, including a pre-occlusion (i.e., before the occlusion procedure) model and correctly and incorrectly occluded post-procedural models, were constructed based on cardiac computed tomography images from an 86-year-old male with long-standing persistent AF. A custom-made closed-loop flow circuit was set up, and pulsatile simulated pulmonary venous flow was delivered by a pump. 4D flow MRI was performed using a 3T scanner, and the images were analyzed using MATLAB-based software (R2020b; Mathworks). Flow metrics associated with blood stasis and thrombogenicity, such as the volume of stasis defined by the velocity threshold (|V → | < 3 cm/s), surface-andtime- averaged wall shear stress (WSS), and endothelial cell activation potential (ECAP), were analyzed and compared among the three LA phantom models. Results: Different spatial distributions, orientations, and magnitudes of LA flow were directly visualized within the three LA phantoms using 4D flow MRI. The time-averaged volume and its ratio to the corresponding entire volume of LA flow stasis were consistently reduced in the correctly occluded model (70.82 mL and 39.0%, respectively), followed by the incorrectly occluded (73.17 mL and 39.0%, respectively) and pre-occlusion (79.11 mL and 39.7%, respectively) models. The surfaceand- time-averaged WSS and ECAP were also lowest in the correctly occluded model (0.048 Pa and 4.004 Pa-1, respectively), followed by the incorrectly occluded (0.059 Pa and 4.792 Pa-1, respectively) and pre-occlusion (0.072 Pa and 5.861 Pa-1, respectively) models.Conclusion: These findings suggest that a correctly occluded LAA leads to the greatest reduction in LA flow stasis and thrombogenicity, presenting a tentative procedural goal to maximize clinical benefits in patients with AF.
Files in This Item
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sang Wook photo

Kim, Sang Wook
의과대학 (의학부(임상-광명))
Read more

Altmetrics

Total Views & Downloads

BROWSE