Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison between Conventional Breath-hold and Respiratory-triggered Magnetic Resonance Cholangiopancreatography with and without Compressed Sensing: Cross-sectional Studyopen access

Authors
Kim, YoungukLee, Eun SunPark, Hyun JeongPark, Sung BinKuehn, BerndSung, Jae KonLim, YaejiKim, Changwoo
Issue Date
2024
Publisher
Bentham Science Publishers
Keywords
Breath holding; Cholangiopancreatography; Data compression; Image enhancement; Magnetic resonance; Respiratory-gated imaging techniques
Citation
Current Medical Imaging, v.20
Journal Title
Current Medical Imaging
Volume
20
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/70698
DOI
10.2174/1573405620666230328093206
ISSN
1573-4056
1875-6603
Abstract
Introduction: The application of compressed sensing (CS) has enabled breath-hold 3D-MRCP with a shorter acquisition time in clinical practice. Aim: To compare the image quality of breath-hold (BH) and respiratory-triggered (RT) 3D-MRCP with or without CS application in the same study population. Methods: In this retrospective study, from February to July 2020, a total of 98 consecutive patients underwent four different acquisition types of 3D-MRCP.; 1) BH MRCP with the generalized autocalibrating partially parallel acquisition (GRAPPA) (BH-GRAPPA), 2) RT-GRAPPA-MRCP, 3) RT-CS-MRCP and 4) BH-CS-MRCP. Relative contrast of common bile duct, 5-scale visibility score of biliary pancreatic ducts, 3-scale artifact score and 5-scale overall image quality score were evaluated by two abdominal radiologists. Results: Relative contrast value was significantly higher in BH-CS or RT-CS than in RT-GRAPPA (0.90 ± 0.057 and 0.89 ± 0.079, respectively, vs. 0.82 ± 0.071, p < 0.01) or BH-GRAPPA (vs. 0.77 ± 0.080, p < 0.01). The area affected by artifact was significantly lower in BH-CS among 4 MRCPs (p < 0.01). Overall image quality score in BH-CS was significantly higher than BH-GRAPPA (3.40 vs. 2.71, p < 0.01). There were no significant differences between RT-GRAPPA and BH-CS (vs. 3.13, p = 0.67) in overall image quality. Conclusion: In this study, our results revealed BH-CS had higher relative contrast and comparable or superior image quality among four MRCP sequences. © 2024 The Author(s). Published by Bentham Science Publisher.
Files in This Item
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Yae Ji photo

Lim, Yae Ji
대학원 (통계데이터사이언스학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE