Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Quantitative Label-free Determination of Thrombin Using a Chemically-modified M13 Virus-electrode Interface

Authors
Shin, Jae HwanYang, Hyo JeongKim, Ji HongYang, Jin ChulPark, JinyoungPark, Jong Pil
Issue Date
Apr-2023
Publisher
Korean Society for Biotechnology and Bioengineering
Keywords
affinity peptide; electrochemical sensor; M13 phage; phage display; thrombin
Citation
Biotechnology and Bioprocess Engineering, v.28, no.2, pp 235 - 245
Pages
11
Journal Title
Biotechnology and Bioprocess Engineering
Volume
28
Number
2
Start Page
235
End Page
245
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/70706
DOI
10.1007/s12257-022-0361-9
ISSN
1226-8372
1976-3816
Abstract
The use of affinity peptide displaying on the surface of M13 phage has emerged as a promising alternative to antibody-based detection methods owing to its diverse structure, mass production, easy purification, and genetic manipulation, as well as excellent stability. In this study, we aimed to identify highly selective and sensitive peptide-displayed M13 phage for thrombin detection using phage display technology. Phage display was conducted using two different phage libraries (linear and cyclic forms of peptides), which displayed affinity peptides capable of binding specifically to thrombin. Throughout the biopanning process, two phage clones that displayed both peptides (WGQSFWGYQHYS and CWKLLTPWC) were selected. After the characterization of their binding abilities using enzyme-linked immunosorbent assay, whole phage particles were covalently attached to a gold electrode using MUA-EDC/NHS coupling chemistry. The thrombin detection mechanism was based on signal inhibition, and the results revealed that the specific interactions between the phage-tethered gold electrode and thrombin are critical factors affecting the decrease in the peak current of the sensor. In addition, under optimal conditions, the fabricated phage-based electrochemical sensors were capable of highly sensitive and specific thrombin detection with a good binding affinity (Kd = 17 nM for 12mer 3–17 and 14 nM for C7C 3–5) and limit of detection (4 nM for 12mer 3–17 and 10 nM for C7C 3–5), resulting in good reproducibility, even in artificial human plasma samples. This study may provide an alternative and more efficient method of detecting thrombin with desirable sensitivity, selectivity, and feasibility for the diagnosis and prognosis of coagulation disorder-related diseases. © 2023, The Korean Society for Biotechnology and Bioengineering and Springer.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jong Pil photo

Park, Jong Pil
대학원 (식품생명공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE