Performance of 1-mm non-gated low-dose chest computed tomography using deep learning-based noise reduction for coronary artery calcium scoring
- Authors
- Choi, H.; Park, E.-A.; Ahn, C.; Kim, J.-H.; Lee, W.; Jeong, B.
- Issue Date
- Jun-2023
- Publisher
- Springer Science and Business Media Deutschland GmbH
- Keywords
- Coronary artery disease; Deep learning; Image processing, Computer-assisted; Tomography, X-ray computed
- Citation
- European Radiology, v.33, no.6, pp 3839 - 3847
- Pages
- 9
- Journal Title
- European Radiology
- Volume
- 33
- Number
- 6
- Start Page
- 3839
- End Page
- 3847
- URI
- https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/71110
- DOI
- 10.1007/s00330-022-09300-6
- ISSN
- 0938-7994
1432-1084
- Abstract
- Objective: To investigate performance of 1-mm, sharp kernel, low-dose chest computed tomography (LDCT) for coronary artery calcium scoring (CACS) using deep learning (DL)–based denoising technique. Methods: This retrospective, intra-individual comparative study consisted of four image datasets of 131 participants who underwent LDCT and calcium CT on the same day between January and February 2020; 1-mm LDCT with DL, 1-mm LDCT with iterative reconstruction (IR), 3-mm LDCT, and calcium CT. CACS from calcium CT were considered as reference and CACS were categorized as 0, 1–10, 11–100, 101–400, and > 400. We compared CACS from LDCTs with that from calcium CT. Results: Mean CACS was 104.8 ± 249.1 and proportion of positive CACS was 45% (59/131). CACS from LDCT images tended to be underestimated than those from calcium CT: 1-mm LDCT with DL (93.5 ± 249.6, p = 0.002), 1-mm LDCT with IR (94.7 ± 249.9, p < 0.001), and 3-mm LDCT (90.3 ± 245.3, p = 0.004). All LDCT datasets showed excellent agreement with calcium CT: intraclass correlation coefficient (ICC) = 0.961 (95% confidence interval (CI), 0.945–0.972) for DL, 0.969 (95% CI, 0.956–0.978) for IR, and 0.952 (95% CI, 0.932–0.966) for 3-mm LDCT; weighted kappa for CACS classification, 0.930 (95% CI, 0.893–0.966) for 1-mm LDCT with DL, 0.908 (95% CI, 0.866–0.950) for 1-mm LDCT with IR, and 0.846 (95% CI, 0.780–0.912) for 3-mm LDCT. The accuracy of CACS classification of 1-mm LDCT with DL (90%) tended to be better than 1-mm LDCT with IR (87%) and 3-mm LDCT (84.7%) (p = 0.10). Conclusion: DL-based noise reduction algorithm can offer reliable calcium scores in 1-mm LDCT reconstructed with sharp kernel. Key Points: • Deep learning (DL)–based noise reduction enables calcium scoring at 1-mm, sharp kernel reconstructed low-dose chest CT (LDCT). • Both iterative reconstruction and DL-based noise reduction underestimated calcium score, but agreement were excellent with those from calcium CT. • Accuracy of categorical classification of calcium scoring tended to be highest in 1-mm LDCT with DL compared to 1-mm LDCT with IR and 3-mm LDCT (90%, 87%, and 84.7%, p = 0.10). © 2022, The Author(s), under exclusive licence to European Society of Radiology.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - ETC > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.