Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Substitution with Low-Osmolar Iodinated Contrast Agent to Minimize Recurrent Immediate Hypersensitivity Reaction

Authors
Kim, SujeongJeon, Kyung NyeoJung, Jae-WooPark, Han-KiLee, WhalLee, JongminKang, Hye-Ryun
Issue Date
Oct-2023
Publisher
RADIOLOGICAL SOC NORTH AMERICA (RSNA)
Citation
Radiology, v.309, no.1
Journal Title
Radiology
Volume
309
Number
1
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/71193
DOI
10.1148/radiol.222467
ISSN
0033-8419
1527-1315
Abstract
Background The recurrence of hypersensitivity reaction (HSR) to low-osmolar iodinated contrast media (LOCM) remains challenging despite premedication and substitution of the LOCM. Purpose To determine the optimal practical preventive strategy for LOCM substitution in patients with a history of prior immediate HSR to LOCM. Materials and Methods In a retrospective study, patients with an immediate HSR to LOCM before February 2020 and who underwent subsequent exposure to LOCM until March 2021 were enrolled in five tertiary referral hospitals in South Korea. The association of recurrence of an HSR after subsequent LOCM exposures was assessed using multivariate general estimating equation analysis according to age, sex, the severity of the index HSR, premedication, and substituting LOCM based on common carbamoyl side chains, including the N-(2,3-dihydroxypropyl)-carbamoyl and N-(2,3-dihydroxypropyl)-N-methyl-carbamoyl moieties. Results The evaluation included 3800 subsequent LOCM exposures in 1066 patients (mean age, 56.2 years ± 13.5 [SD]; 567 [53%] female and 499 [47%] male patients). The general estimating equation analysis, using 1:1 propensity score matched data for age, sex, HSR severity, and LOCM selection, showed that premedication with corticosteroids significantly reduced recurrent HSR (odds ratio [OR], 0.72; 95% CI: 0.52, 1.00; P = .049). The change to another LOCM with a common side chain had a similar recurrence rate as using the same LOCM (OR, 0.98; 95% CI: 0.64, 1.50; P = .93), whereas the use of a different LOCM without a common side chain significantly lowered HSR recurrence (OR, 0.51; 95% CI: 0.37, 0.69; P < .001) in multivariate general estimating equation analysis. Substitution of an LOCM without a common side chain was effective regardless of the index HSR severity but was more pronounced in moderate-to-severe reactions (OR, 0.30; 95% CI: 0.16, 0.55; P < .001). Conclusion For patients with a previous immediate HSR of any severity to LOCM, alternative LOCM without a common carbamoyl side chain reduced recurrent HSR during subsequent exposures. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by McDonald in this issue.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jung, Jae Woo photo

Jung, Jae Woo
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE