Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Sixty-four-fold data reduction of chest radiographs using a super-resolution convolutional neural network

Authors
Nam, Ju GangKang, Seung KwanChoi, HyewonHong, WonjuPark, JongsooGoo, Jin MoLee, Jae SungPark, Chang Min
Issue Date
Feb-2024
Publisher
BRITISH INST RADIOLOGY
Keywords
deep learning; radiography; computer-assisted image processing
Citation
BRITISH JOURNAL OF RADIOLOGY, v.97, no.1155, pp 632 - 639
Pages
8
Journal Title
BRITISH JOURNAL OF RADIOLOGY
Volume
97
Number
1155
Start Page
632
End Page
639
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/72907
DOI
10.1093/bjr/tqae006
ISSN
0007-1285
1748-880X
Abstract
Objectives To develop and validate a super-resolution (SR) algorithm generating clinically feasible chest radiographs from 64-fold reduced data. Methods An SR convolutional neural network was trained to produce original-resolution images (output) from 64-fold reduced images (input) using 128 x 128 patches (n = 127 030). For validation, 112 radiographs-including those with pneumothorax (n = 17), nodules (n = 20), consolidations (n = 18), and ground-glass opacity (GGO; n = 16)-were collected. Three image sets were prepared: the original images and those reconstructed using SR and conventional linear interpolation (LI) using 64-fold reduced data. The mean-squared error (MSE) was calculated to measure similarity between the reconstructed and original images, and image noise was quantified. Three thoracic radiologists evaluated the quality of each image and decided whether any abnormalities were present. Results The SR-images were more similar to the original images than the LI-reconstructed images (MSE: 9269 +/- 1015 vs. 9429 +/- 1057; P = .02). The SR-images showed lower measured noise and scored better noise level by three radiologists than both original and LI-reconstructed images (Ps < .01). The radiologists' pooled sensitivity with the SR-reconstructed images was not significantly different compared with the original images for detecting pneumothorax (SR vs. original, 90.2% [46/51] vs. 96.1% [49/51]; P = .19), nodule (90.0% [54/60] vs. 85.0% [51/60]; P = .26), consolidation (100% [54/54] vs. 96.3% [52/54]; P = .50), and GGO (91.7% [44/48] vs. 95.8% [46/48]; P = .69). Conclusions SR-reconstructed chest radiographs using 64-fold reduced data showed a lower noise level than the original images, with equivalent sensitivity for detecting major abnormalities. Advances in knowledge This is the first study applying super-resolution in data reduction of chest radiographs.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Hye Won photo

Choi, Hye Won
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE