Detailed Information

Cited 11 time in webofscience Cited 9 time in scopus
Metadata Downloads

Rapid chiral separation of racemic cetirizine in human plasma using subcritical fluid chromatography-tandem mass spectrometry

Authors
Eom, Han YoungKang, MyungheeKang, Seung WooKim, UnyongSuh, Joon HyukKim, JunghyunCho, Hyun-DeokJung, YuraYang, Dong-HyugHan, Sang Beom
Issue Date
Jan-2016
Publisher
ELSEVIER SCIENCE BV
Keywords
Subcritical fluid chromatography; Mass spectrometry; Chiral separation; Cetirizine; Enantiomer; Response surface methodology
Citation
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, v.117, pp 380 - 389
Pages
10
Journal Title
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Volume
117
Start Page
380
End Page
389
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/7380
DOI
10.1016/j.jpba.2015.09.012
ISSN
0731-7085
1873-264X
Abstract
A method for fast chiral separation of cetirizine and quantitation of levocetirizine in human plasma using subcritical fluid chromatography with tandem mass spectrometry was developed and validated. The chromatographic separation was performed using a Chiralpak LE column (2.1 mm x 150 mm, 5 pm) with an isocratic elution of CO2/organic modifier (55/45, v/v) at a flow rate of 0.85 mL/min. The organic modifier was composed of water/methanol (5/95, v/v). The makeup flow was optimized at water/methanol (10/90, v/v) and 0.2 mL/min. The most influential parameters on the separation of cetirizine affecting resolution, retention time and sensitivity were selected by fractional factorial design. The 3 selected factors were optimized by response surface methodology. Tandem mass spectrometry was used at electrospray ionization, positive ion mode, and multiple-reaction monitoring mode. Isotope-labeled cetirizine-d(4) was used as the internal standard. The sample preparation of human plasma was conducted by solid phase extraction of hydrophilic-lipophilic balance (HLB) type. The developed method was validated for selectivity, linearity, precision, accuracy, recovery, limit of quantitation (LOQ), and limit of detection (LOD). The real human plasma samples were analyzed and the pharmacokinetic results were compared with results of previous research. The developed method was found to be reliable based on the similarity between the results of the current and previous methods. The chiral separation for cetirizine and economic feasibility were compared with those of previous studies using normal phase-HPLC or reversed phase-HPLC. The established analytical method could be successfully applied to pharmacokinetic study with reduction in the analysis time and costs. (C) 2015 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Pharmacy > School of Pharmacy > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang Beom photo

Han, Sang Beom
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE