An Image-Based Reduction of Metal Artifacts in Computed Tomography

Authors
Pua, RizzaWi, SunheePark, MiranLee, Jung-RyunCho, Seungryong
Issue Date
Jan-2016
Publisher
LIPPINCOTT WILLIAMS & WILKINS
Keywords
algorithm; artifact reduction; CT; metal artifact
Citation
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, v.40, no.1, pp 131 - 141
Pages
11
Journal Title
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY
Volume
40
Number
1
Start Page
131
End Page
141
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/7458
DOI
10.1097/RCT.0000000000000316
ISSN
0363-8715
1532-3145
Abstract
Objective: Various strategies have been developed in the past to reduce the excessive effects of metal artifacts in computed tomography images. From straightforward sinogram inpainting-based methods to computationally expensive iterative methods, all have been successful in improving the image quality up to a certain degree. We propose a novel image-based metal artifact subtraction method that achieves a superior image quality and at the same time provides a quantitatively more accurate image. Methods: Our proposed method consists of prior image-based sinogram inpainting, metal sinogram extraction, and metal artifact image subtraction. Reconstructing the metal images from the extracted metal-contaminated portions in the sinogram yields a streaky image that eventually can be subtracted from the uncorrected image. The prior image is reconstructed from the sinogram that is free from the metal-contaminated portions by use of a total variation (TV) minimization algorithm, and the reconstructed prior image is fed into the forward projector so that the missing portions in the sinogram can be recovered. Image quality of the metal artifact reduced images on selected areas was assessed by the structure similarity index for the simulated data and SD for the real dental data. Results: Simulation phantom studies showed higher structure similarity index values for the proposed metal artifact reduction (MAR) images than the standard MAR images. Thus, more artifact suppression was observed in proposed MAR images. In real dental phantom data study, lower SD values were calculated from the proposed MAR images. The findings in real human arm study were also consistent with the results in all phantom studies. Thus, compared with standard MAR images, lesser artifact intensity was exhibited by the proposed MAR images. Conclusions: From the quantitative calculations, our proposed method has shown to be effective and superior to the conventional approach in both simulation and real dental phantom cases.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of ICT Engineering > School of Electrical and Electronics Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jung Ryun photo

Lee, Jung Ryun
창의ICT공과대학 (전자전기공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE