Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Automated eyeball volume measurement based on CT images using neural network-based segmentation and simple estimation

Full metadata record
DC Field Value Language
dc.contributor.authorHan, Sujeong-
dc.contributor.authorLee, Jeong Kyu-
dc.contributor.authorLee, Daewon-
dc.contributor.authorLee, Jaesung-
dc.date.accessioned2024-07-26T00:30:39Z-
dc.date.available2024-07-26T00:30:39Z-
dc.date.issued2024-07-
dc.identifier.issn2045-2322-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/75198-
dc.description.abstractWith the increase in the dependency on digital devices, the incidence of myopia, a precursor of various ocular diseases, has risen significantly. Because myopia and eyeball volume are related, myopia progression can be monitored through eyeball volume estimation. However, existing methods are limited because the eyeball shape is disregarded during estimation. We propose an automated eyeball volume estimation method from computed tomography images that incorporates prior knowledge of the actual eyeball shape. This study involves data preprocessing, image segmentation, and volume estimation steps, which include the truncated cone formula and integral equation. We obtained eyeball image masks using U-Net, HFCN, DeepLab v3 +, SegNet, and HardNet-MSEG. Data from 200 subjects were used for volume estimation, and manually extracted eyeball volumes were used for validation. U-Net outperformed among the segmentation models, and the proposed volume estimation method outperformed comparative methods on all evaluation metrics, with a correlation coefficient of 0.819, mean absolute error of 0.640, and mean squared error of 0.554. The proposed method surpasses existing methods, provides an accurate eyeball volume estimation for monitoring the progression of myopia, and could potentially aid in the diagnosis of ocular diseases. It could be extended to volume estimation of other ocular structures. © 2024. The Author(s).-
dc.language영어-
dc.language.isoENG-
dc.publisherNATURE PORTFOLIO-
dc.titleAutomated eyeball volume measurement based on CT images using neural network-based segmentation and simple estimation-
dc.typeArticle-
dc.identifier.doi10.1038/s41598-024-64913-9-
dc.identifier.bibliographicCitationScientific reports, v.14, no.1-
dc.description.isOpenAccessY-
dc.identifier.wosid001262145700014-
dc.identifier.scopusid2-s2.0-85197598364-
dc.citation.number1-
dc.citation.titleScientific reports-
dc.citation.volume14-
dc.type.docTypeArticle-
dc.publisher.location영국-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
Appears in
Collections
College of Software > Department of Artificial Intelligence > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jaesung photo

Lee, Jaesung
소프트웨어대학 (AI학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE