Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Stent underexpansion is associated with high wall shear stress: a biomechanical analysis of the shear stent study

Authors
Kumar, SonaliMolony, DavidKhawaja, SameerCrawford, KaylynThompson, Elizabeth W.Hung, OliviaShah, ImranNavas-Simbana, JessicaHo, ArlenKumar, ArnavKo, Yi-AnHosseini, HosseinLefieux, AdrienLee, Joo MyungHahn, Joo-YongChen, Shao-LiangOtake, HiromasaAkasaka, TakashiShin, Eun-SeokKoo, Bon-KwonStankovic, GoranMilasinovic, DejanNam, Chang-WookWon, Ki-BumEscaned, JavierErglis, AndrejsMurasato, YoshinobuVeneziani, AlessandroSamady, Habib
Issue Date
Jul-2023
Publisher
SPRINGER
Keywords
Intravascular ultrasound; Underexpansion; Wall shear stress; Percutaneous coronary intervention
Citation
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, v.39, no.7, pp 1375 - 1382
Pages
8
Journal Title
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING
Volume
39
Number
7
Start Page
1375
End Page
1382
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/75316
DOI
10.1007/s10554-023-02838-6
ISSN
1569-5794
1573-0743
Abstract
Coronary stent underexpansion is associated with restenosis and stent thrombosis. In clinical studies of atherosclerosis, high wall shear stress (WSS) has been associated with activation of prothrombotic pathways, upregulation of matrix metalloproteinases, and future myocardial infarction. We hypothesized that stent underexpansion is predictive of high WSS. WSS distribution was investigated in patients enrolled in the prospective randomized controlled study of angulated coronary arteries randomized to undergo percutaneous coronary intervention with R-ZES or X-EES. WSS was calculated from 3D reconstructions of arteries from intravascular ultrasound (IVUS) and angiography using computational fluid dynamics. A logistic regression model investigated the relationship between WSS and underexpansion and the relationship between underexpansion and stent platform. Mean age was 63 +/- 11, 78% were male, 35% had diabetes, mean pre-stent angulation was 36.7 degrees +/- 14.7 degrees. Underexpansion was assessed in 83 patients (6,181 IVUS frames). Frames with stent underexpansion were significantly more likely to exhibit high WSS (> 2.5 Pa) compared to those without underexpansion with an OR of 2.197 (95% CI = [1.233-3.913], p = 0.008). There was no significant association between underexpansion and low WSS (< 1.0 Pa) and no significant differences in underexpansion between R-ZES and X-EES. In the Shear Stent randomized controlled study, underexpanded IVUS frames were more than twice as likely to be associated with high WSS than frames without underexpansion.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.