오피스 건물의 실내 환경 실태 조사The Field Survey of Indoor Environment of the Office Building
- Authors
- Yang, Young Kwon; Kang, In Sung; Chung, Min Hee; Moon, Jin Woo; Park, Jin Chul
- Issue Date
- Jun-2016
- Publisher
- 한국생태환경건축학회
- Keywords
- 실내환경; 실내공기질; 온열환경; 음환경; 빛환경; Indoor Environment; Indoor Air Quality; Thermal Environment; Acoustical Environment; Lighting Environment
- Citation
- KIEAE Journal, v.16, no.3, pp 71 - 76
- Pages
- 6
- Journal Title
- KIEAE Journal
- Volume
- 16
- Number
- 3
- Start Page
- 71
- End Page
- 76
- URI
- https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/8133
- DOI
- 10.12813/kieae.2016.16.3.071
- ISSN
- 2288-968X
2288-9698
- Abstract
- Purpose: This study aimed at improving the indoor environment of the office building by measuring the indoor environment and conducting a survey. Method: The measurement was conducted from January 13 to March 16 in 2012, targeting 44 sites in same office building located in Seoul, South Korea. The lists of measurement such as dry-blub temperature, relative humidity, formaldehyde (HCHO), asbestos, carbon monoxide (CO), carbon dioxide (CO2), volatile organic compounds (VOCs) and particle pollution (PM10) were measured. In addition, illuminance which belongs to light environment and noise in sound[acoustical] environment were measured respectively. Result: The buildings showed overall pleasant conditions. In terms of the thermal, air, sound, and visual environment, each measurements were satisfied with the requirements in standard, within pleasant ranges, except several sites. However, the survey results were revealed that the office workers were mostly dissatisfied with their indoor environment. Given that the measured values were mostly within standards, the results of survey might have resulted from a compensation mentality biased toward the subjects in psychological terms
Purpose: This study aimed at improving the indoor environment of the office building by measuring the indoor environment and conducting a survey. Method: The measurement was conducted from January 13 to March 16 in 2012, targeting 44 sites in same office building located in Seoul, South Korea. The lists of measurement such as dry-blub temperature, relative humidity, formaldehyde (HCHO), asbestos, carbon monoxide (CO), carbon dioxide (CO2), volatile organic compounds (VOCs) and particle pollution (PM10) were measured. In addition, illuminance which belongs to light environment and noise in sound[acoustical] environment were measured respectively. Result: The buildings showed overall pleasant conditions. In terms of the thermal, air, sound, and visual environment, each measurements were satisfied with the requirements in standard, within pleasant ranges, except several sites. However, the survey results were revealed that the office workers were mostly dissatisfied with their indoor environment. Given that the measured values were mostly within standards, the results of survey might have resulted from a compensation mentality biased toward the subjects in psychological terms