Detailed Information

Cited 3 time in webofscience Cited 3 time in scopus
Metadata Downloads

Effects of bed height on the performance of endotracheal intubation and bag mask ventilation

Authors
Hong, Jun YoungOh, Je HyeokKim, Chan WoongKim, Sung EunLee, Dong HoonShin, Jung-Ho
Issue Date
Oct-2016
Publisher
PHARMAMED MADO LTD
Keywords
endotracheal intubation; positive pressure ventilation; bed; cardiopulmonary resuscitation
Citation
SIGNA VITAE, v.12, no.S1, pp 47 - 51
Pages
5
Journal Title
SIGNA VITAE
Volume
12
Number
S1
Start Page
47
End Page
51
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/8779
DOI
10.22514/SV121.102016.8
ISSN
1334-5605
1845-206X
Abstract
Objectives. This study was performed to evaluate whether different bed heights affect the performance of airway procedures. Methods. Thirty three medical doctors performed endotracheal intubation (EI) and bag mask ventilation (BMV) using three different bed heights; knee height, mid-thigh height, and anterior superior iliac spine (ASIS) height. For El, performance was assessed based on intubation time, intubation success, and damage to teeth. For BMV, performance was assessed based on tidal volume, ventilation rate, peak pressure, minute ventilation, and airway opening. In addition, three numeric rating scales (NRS; 1 to 10) were used to assess the level of difficulty for each procedure and the doctors' self-confidence. NRS scoring was based on posture (comfortable to uncomfortable), handling (easy to hard), and visual field (good to bad). Results. No significant differences in performance were observed for El or BMV at the three different bed heights. However, all of the NRS scores were significantly different among the different bed heights (P<0.001), and were poorest for the knee height beds: knee height (EI: posture 5.8 similar to 7.3, handling 4.3 similar to 5.7, visual field 3.9 similar to 5.5; BMV: posture 7.1 similar to 8.0, handling 5.9 similar to 7.2, 95% CI), mid-high height (EI: posture 2.9 similar to 4.0, handling 2.9 similar to 4.0, visual field 2.7 similar to 3.8; BMV: posture 2.4 similar to 3.2, handling 2.3 similar to 3.5) and ASIS height (EI: posture 2.2 similar to 3.5, handling 2.6 similar to 3.8, visual field 2.1 similar to 3.4; BMV: posture 2.9 similar to 4.4, handling 4.7 similar to 6.1). Conclusions. Although the participants reported that the knee height beds were the least comfortable, hardest to handle, and made seeing the vocal cord difficult, these caveats did not affect their performance during airway procedures.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sung Eun photo

Kim, Sung Eun
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE