Detailed Information

Cited 21 time in webofscience Cited 22 time in scopus
Metadata Downloads

Knowledge-based iterative model reconstruction (IMR) algorithm in ultralow-dose CT for evaluation of urolithiasis: evaluation of radiation dose reduction, image quality, and diagnostic performance

Authors
Bin Park, SungKim, Yang SooLee, Jong BeumPark, Hyun Jeong
Issue Date
Oct-2015
Publisher
SPRINGER
Keywords
Knowledge-based iterative model reconstruction; Model-based iterative reconstruction; Statistical iterative reconstruction; Urolithiasis; Low-dose computed tomography
Citation
ABDOMINAL IMAGING, v.40, no.8, pp 3137 - 3146
Pages
10
Journal Title
ABDOMINAL IMAGING
Volume
40
Number
8
Start Page
3137
End Page
3146
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/9065
DOI
10.1007/s00261-015-0504-y
ISSN
0942-8925
1432-0509
Abstract
To evaluate the efficacy of a knowledge-based iterative model reconstruction (IMR) algorithm for reducing image noise in ultralow-dose (ULD) CT for urolithiasis. A total of 103 patients diagnosed with urinary stones (n = 276) were enrolled. Regular dose (RD) scans (120 kV and 150 mAs, maximal tube current in dose modulation) were reconstructed using filtered back-projection (FBP, RD-FBP), and ULD scans (100 kV and 20 mAs, fixed tube current) were reconstructed with FBP (ULD-FBP), statistical iterative reconstruction (IR; ULD-iDose), and a knowledge-based IMR algorithm (ULD-IMR). Prospective interpretations of the two scans were performed with respect to radiation dose, objective image noise, and subjective assessment. The subjective assessment was also evaluated with regard to each patient's body mass index (BMI, < 25 or a parts per thousand yen25 kg/m(2)). Using RD CT (RD-FBP) as the reference standard, two reviewers assessed the diagnostic performance and inter-observer agreement for ULD-IMR. The average effective doses with RD CT and ULD CT were 8.31 and 0.68 mSv, respectively, and the average radiation dose reduction rate was 91.82% (p < 0.01). The lowest objective image noise was observed with ULD-IMR (p < 0.01). Subjective assessment in ULD-IMR was comparable to that of RD-FBP, although RD-FBP remained statistically superior. For BMI, there was a statistically significant difference in subjective image quality between the normal (4.7 +/- A 0.54) and overweight or obese groups (4.2 +/- A 0.5) (p < 0.05). The ULD-IMR showed a greater than 75% concordant rate in overall stones and 100% in ureter stones larger than 3 mm. However, for stones < 3 mm, neither reviewer had a good detection rate (45.5% and 56.9% for the general and genitourinary radiologist, respectively). Inter-observer agreement was almost perfect (kappa = 0.82). Despite a significant radiation dose reduction, ULD-IMR images were comparable in image quality and noise to RD-FBP images. Furthermore, the diagnostic performance of the ULD non-enhanced CT protocol was comparable to that of the RD scan for diagnosing urinary stones larger than 3 mm.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Hyun Jeong photo

Park, Hyun Jeong
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE