Detailed Information

Cited 19 time in webofscience Cited 21 time in scopus
Metadata Downloads

Removal of acetaminophen and naproxen by combined coagulation and adsorption using biochar: influence of combined sewer overflow components

Authors
Jung, ChanilOh, JeillYoon, Yeomin
Issue Date
Jul-2015
Publisher
SPRINGER HEIDELBERG
Keywords
Activated biochar; Nonsteroidal anti-inflammatory drugs; Combined sewer overflows; Freundlich isotherm; Natural organic matter; Inorganics
Citation
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, v.22, no.13, pp 10058 - 10069
Pages
12
Journal Title
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH
Volume
22
Number
13
Start Page
10058
End Page
10069
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/9387
DOI
10.1007/s11356-015-4191-6
ISSN
0944-1344
1614-7499
Abstract
The combined coagulation and adsorption of targeted acetaminophen and naproxen using activated biochar and aluminum sulfate were studied under various synthetic "combined sewer overflow" (CSO) conditions. The biochar demonstrated better adsorption performance for both acetaminophen and naproxen (removal, 94.1 and 97.7 %, respectively) than that of commercially available powdered activated carbon (removal, 81.6 and 94.1 %, respectively) due to superior carbonaceous structure and surface properties examined by nuclear magnetic resonance analysis. The adsorption of naproxen was more favorable, occupying active adsorption sites on the adsorbents by naproxen due to its higher adsorption affinity compared to acetaminophen. Three classified CSO components (i.e., representing hydrophobic organics, hydrophilic organics, and inorganics) played different roles in the adsorption of both adsorbates, resulted in inhibition by humic acid complexation or metal ligands and negative electrostatic repulsion under adsorption and coagulation combined system. Adsorption alone with biochar was determined to be the most effective adsorptive condition for the removal of both acetaminophen and naproxen under various CSO conditions, while both coagulation alone and combined adsorption and coagulation failed to remove the acetaminophen and naproxen adequately due to an increase in ionic strength in the presence of spiked aluminum species derived from the coagulant.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Je Ill photo

Oh, Je Ill
공과대학 (건설환경플랜트공학)
Read more

Altmetrics

Total Views & Downloads

BROWSE