Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of progressive collapse resistance capacities of steel ordinary and intermediate moment frames considering different connection details

Authors
Lee, Sang-YunNoh, Sam-YoungLee, Dongkeun
Issue Date
Mar-2021
Publisher
Pergamon Press Ltd.
Keywords
Progressive collapse; WUF-B connection; RBS connection; Moment frames; Equivalent energy-based approximate analysis; Structural robustness
Citation
Engineering Structures, v.231, pp 1 - 13
Pages
13
Indexed
SCIE
SCOPUS
Journal Title
Engineering Structures
Volume
231
Start Page
1
End Page
13
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/108330
DOI
10.1016/j.engstruct.2020.111753
ISSN
0141-0296
1873-7323
Abstract
In this study, the progressive collapse resistance capacities of steel ordinary moment frames (OMFs) and intermediate moment frames (IMFs) with different connection details were numerically evaluated and compared. Three prototype buildings with typical configurations were designed in accordance with Korean building code (KBC). OMFs with welded unreinforced flange-bolted web (WUF-B) connections, OMFs with reduced beam section (RBS) ones, and IMFs with RBS ones were deployed for each building. Beams, columns, connections, and composite slabs were modeled using reduced models of 1-D and 2-D elements for efficient analyses. With respect to progressive collapse analyses, 1and 2-column removal scenarios were firstly performed through non-linear static analyses and then the numerical results were employed for the energy-based approximate analyses, resulting in load-displacement relationships reflecting dynamic effects due to the sudden column removals without highly time-consuming dynamic analyses. The comparison of progressive collapse resistance capacities was based on the U.S. general services administration (GSA), structural robustness index, and sensitivity index. As a result, all the three buildings met the chord rotation criterion of GSA and indicated enough resistance capacities in the 1-column removal scenario, but not in the 2-column removal scenario. For the OMFs, it was found that the RBS connection showed better resistance capacity than the WUF-B one. Furthermore, the OMFs were superior to the IMFs from the standpoint of resistance capacity. The results can be utilized to predict progressive collapse resistance capacities of similar types of structures.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Noh, Sam Young photo

Noh, Sam Young
ERICA 공학대학 (MAJOR IN ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE