Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Divulge of Root Cause Failure in Individual Cells of 2x nm Technology DDR4 DRAM at Operating Temperature

Authors
Shahzadi, NosheenPark, MyungsangYun, DonghyukBaeg, Sanghyeon
Issue Date
May-2022
Publisher
Institute of Electrical and Electronics Engineers
Keywords
Temperature measurement; Random access memory; Temperature distribution; Tail; Time measurement; Heating systems; Market research; Activation energy (Ea); double data rate (DDR)4; dynamic random access memory (DRAM); gate induced drain leakage (GIDL); junction leakage; subthreshold leakage; retention time (tret)
Citation
IEEE Transactions on Electron Devices, v.69, no.5, pp 2338 - 2345
Pages
8
Indexed
SCIE
SCOPUS
Journal Title
IEEE Transactions on Electron Devices
Volume
69
Number
5
Start Page
2338
End Page
2345
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/111281
DOI
10.1109/TED.2022.3159496
ISSN
0018-9383
1557-9646
Abstract
This article reveals the leakage mechanisms corresponding to the dominant leakage path of individual tail cells in 2xnmtechnologydouble data rate (DDR)4DRAM at operating temperature. For leakage path determination, activation energy ( Ea) was used as a tool through its extraction by retention time measurement. To get a wide distribution of Ea, retention testing was performed at the target retention time (10, 15, 20, or 25 s); during this, the number of retentions failed cells were recorded with each temperature. In this experiment, 1.65 e-2% of the selected bank cells found retention failures. From the total retention failed cells, the selected commonly retention failed cells at the target retention times comprise 1.5 e-3% of the selected bank cells. From commonly retention failed cells, the distribution of Ea is analyzed with the retention time at room temperature. This analysis reveals that subthreshold, junction, and gate-induced drain leakage (GIDL) leakage paths dominate in 3.48%, 93.89%, and 2.61% of the total retention failed cells, respectively, at room temperature. Using another experimental approach, retention testing performed at operating temperature on selected 0.07-ppm retention tail cells concludes that GIDL is the dominant leakage path in this device. Correlation between Ea and retention time measured at operating temperature (40 degrees C, 60 degrees C, or 80 degrees C) explored the leakage mechanisms corresponding to Ea of the extracted dominant leakage path (GIDL). These failure leakage mechanisms, dominating on certain values of operating temperature, are divulged as the root cause of failure at that temperature.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Baeg, Sanghyeon photo

Baeg, Sanghyeon
ERICA 공학대학 (SCHOOL OF ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE