Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

New morphological parameter for intracranial aneurysms and rupture risk prediction based on artificial neural networks

Full metadata record
DC Field Value Language
dc.contributor.authorYang, Hyeondong-
dc.contributor.authorCho, Kwang-Chun-
dc.contributor.authorKim, Jung-Jae-
dc.contributor.authorKim, Yong Bae-
dc.contributor.authorOh, Je Hoon-
dc.date.accessioned2023-01-25T09:13:40Z-
dc.date.available2023-01-25T09:13:40Z-
dc.date.issued2022-09-
dc.identifier.issn1759-8478-
dc.identifier.issn1759-8486-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/111392-
dc.description.abstractBackground Numerous studies have evaluated the rupture risk of intracranial aneurysms using morphological parameters because of their good predictive capacity. However, the limitation of current morphological parameters is that they do not always allow evaluation of irregularities of intracranial aneurysms. The purpose of this study is to propose a new morphological parameter that can quantitatively describe irregularities of intracranial aneurysms and to evaluate its performance regarding rupture risk prediction. Methods In a retrospective study, conventional morphological parameters (aspect ratio, bottleneck ratio, height-to-width ratio, volume to ostium ratio, and size ratio) and a newly proposed morphological parameter (mass moment of inertia) were calculated for 125 intracranial aneurysms (80 unruptured and 45 ruptured aneurysms). Additionally, hemodynamic parameters (wall shear stress and strain) were calculated using computational fluid dynamics and fluid-structure interaction. Artificial neural networks trained with each parameter were used for rupture risk prediction. Results All components of the mass moment of inertia (I-xx, I-yy, and I-zz) were significantly higher in ruptured cases than in unruptured cases (p values for I-xx, I-yy, and I-zz were 0.032, 0.047, and 0.039, respectively). When the conventional morphological and hemodynamic parameters as well as the mass moment of inertia were considered together, the highest performance for rupture risk prediction was obtained (sensitivity 96.3%; specificity 85.7%; area under the receiver operating characteristic curve 0.921). Conclusions The mass moment of inertia would be a useful parameter for evaluating aneurysm irregularity and hence its risk of rupture. The new approach described here may help clinicians to predict the risk of aneurysm rupture more effectively.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisherBMJ Publishing Group-
dc.titleNew morphological parameter for intracranial aneurysms and rupture risk prediction based on artificial neural networks-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1136/jnis-2022-019201-
dc.identifier.scopusid2-s2.0-85142855269-
dc.identifier.wosid000861397100001-
dc.identifier.bibliographicCitationJournal of NeuroInterventional Surgery, v.15, no.e2, pp 1 - 7-
dc.citation.titleJournal of NeuroInterventional Surgery-
dc.citation.volume15-
dc.citation.numbere2-
dc.citation.startPage1-
dc.citation.endPage7-
dc.type.docTypeArticle; Early Access-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaNeurosciences & Neurology-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategoryNeuroimaging-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusUNRUPTURED CEREBRAL ANEURYSMS-
dc.subject.keywordPlusASPECT RATIO-
dc.subject.keywordPlusSHAPE-
dc.subject.keywordPlusSIZE-
dc.subject.keywordPlusHEMODYNAMICS-
dc.subject.keywordPlusINDEX-
dc.subject.keywordAuthorAneurysm-
dc.identifier.urlhttps://jnis.bmj.com/content/early/2022/09/26/jnis-2022-019201-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Je Hoon photo

Oh, Je Hoon
ERICA 공학대학 (DEPARTMENT OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE