Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Method for Optimization of a Shielding Effectiveness Measurement System Using Shielding Concrete Blocks for IEMIopen access

Authors
Jang, HongjeChoi, MyungryulSong, TaesuengKim, Sungwook
Issue Date
Nov-2022
Publisher
Institute of Electrical and Electronics Engineers Inc.
Keywords
Shielding concrete; electromagnetic shielding; shielding effectiveness test
Citation
IEEE Access, v.10, pp 118278 - 118289
Pages
12
Indexed
SCIE
SCOPUS
Journal Title
IEEE Access
Volume
10
Start Page
118278
End Page
118289
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/111550
DOI
10.1109/ACCESS.2022.3220768
ISSN
2169-3536
Abstract
The recent digitization of many technologies has made information communication facilities vulnerable to intentional electromagnetic interference (IEMI) and electromagnetic pulses (EMPs). Concrete with shielding capability is being studied to protect entire information facilities or security facilities from these threats. Although the conventional standards ASTM D 4935 and MIL-STD-188-125-1 provide guidelines with regard to the assessment of the shielding effectiveness (SE) of materials, these standards are not applicable to concrete owing to the thickness of concrete, particularly when reinforced with rebar, the composition of building materials, time, and cost. To solve this problem, this paper proposes a method for measuring the SE of concrete used for building construction. The proposed measuring method is based on the MIL-STD-188-125-1 standard. Small concrete blocks are used as specimens for testing the suggested SE measurement method, which is designed to operate in the frequency range of 600 MHz to 1.5 GHz. The accuracy of the proposed method is optimized by varying parameters such as the size of the concrete blocks, incidence angle of electromagnetic waves, fixture materials, and the use of absorbers. The results of the proposed method are compared with those of the ASTM D 4935 standard. The SE of concrete blocks, concrete walls, and concrete buildings is also tested using the proposed method and MIL-STD-188-125-1. Similar results were obtained with all of these methods. Therefore, the proposed method to measure the SE of concrete blocks might be suitable to ascertain that buildings constructed with the same concrete could be expected to have the same SE.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHOI, MYUNG RYUL photo

CHOI, MYUNG RYUL
ERICA 공학대학 (SCHOOL OF ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE