dc.description.abstract | Background Computational fluid dynamics (CFD) is widely used to calculate hemodynamic parameters that are known to influence cerebral aneurysms. However, the boundary conditions for CFD are chosen without any specific criteria. Our objective is to establish the recommendations for setting the analysis conditions for CFD analysis of the cerebral aneurysm. Method The plug and the Womersley flow were the inlet boundary conditions, and zero and pulsatile pressures were the outlet boundary conditions. In addition, the difference in the assumption of viscosity was analyzed with respect to the flow rate. The CFD process used in our research was validated using particle image velocimetry experiment data from Tupin et al.'s work to ensure the accuracy of the simulations. Results It was confirmed that if the entrance length was sufficiently secured, the inlet and outlet boundary conditions did not affect the CFD results. In addition, it was observed that the difference in the hemodynamic parameter between Newtonian and non-Newtonian fluid decreased as the flow rate increased. Furthermore, it was confirmed that similar tendencies were evaluated when these recommendations were utilized in the patient-specific cerebral aneurysm models. Conclusions These results may help conduct standardized CFD analyses regardless of the research group. | - |
dc.format.extent | 12 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Springer Verlag | - |
dc.title | Influence of blood viscosity models and boundary conditions on the computation of hemodynamic parameters in cerebral aneurysms using computational fluid dynamics | - |
dc.type | Article | - |
dc.publisher.location | 오스트리아 | - |
dc.identifier.doi | 10.1007/s00701-022-05467-5 | - |
dc.identifier.scopusid | 2-s2.0-85145887345 | - |
dc.identifier.wosid | 000911233200001 | - |
dc.identifier.bibliographicCitation | Acta Neurochirurgica, v.165, no.2, pp 471 - 482 | - |
dc.citation.title | Acta Neurochirurgica | - |
dc.citation.volume | 165 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 471 | - |
dc.citation.endPage | 482 | - |
dc.type.docType | Article; Early Access | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Neurosciences & Neurology | - |
dc.relation.journalResearchArea | Surgery | - |
dc.relation.journalWebOfScienceCategory | Clinical Neurology | - |
dc.relation.journalWebOfScienceCategory | Surgery | - |
dc.subject.keywordPlus | FLOW | - |
dc.subject.keywordPlus | RUPTURE | - |
dc.subject.keywordAuthor | Cerebral aneurysm | - |
dc.subject.keywordAuthor | Computational fluid dynamics | - |
dc.subject.keywordAuthor | Analysis conditions | - |
dc.subject.keywordAuthor | Blood viscosity model | - |
dc.subject.keywordAuthor | Hemodynamic parameter | - |
dc.identifier.url | https://link.springer.com/article/10.1007/s00701-022-05467-5 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.