2행1열 듀플렉스계 스테인리스강(STS329FLD) 볼트접합부의 최대내력 조사An Investigation on the Ultimate Strength of Duplex Stainless Steel (STS329FLD) Bolted Connections with Two Bolts

Other Titles
An Investigation on the Ultimate Strength of Duplex Stainless Steel (STS329FLD) Bolted Connections with Two Bolts
Authors
안성호김근영황보경김태수
Issue Date
Sep-2018
Publisher
한국구조물진단유지관리공학회
Keywords
듀플렉스계 스테인리스강; 볼트접합; 면외변형; 내력저하; 일면전단; 이면전단; 설계기준; Duplex stainless steel; Bolted connection; Curling, Strength reduction,; Single shear; Double shear; Design specification
Citation
한국구조물진단유지관리공학회 논문집, v.22, no.5, pp 53 - 63
Pages
11
Indexed
KCI
Journal Title
한국구조물진단유지관리공학회 논문집
Volume
22
Number
5
Start Page
53
End Page
63
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/114230
DOI
10.11112/jksmi.2018.22.5.055
ISSN
2234-6937
2287-6979
Abstract
최근에 오스테나이트와 페라이트의 조직을 갖는 듀플렉스계 스테인리스강이 개발되었고 오스테나이트계 스테인리스강에 비해고강도, 응력부식균열에 대한 고내식성과 재료비절감으로 다양한 산업분야에서 사용량이 증가되고 있다. 그러나, 현재 스테인리스강은 한국건축구조기준에 구조용재료로 지정되어 있지 않고 구조설계기준도 마련되어 있지 않는 실정이다. 이 연구에서는 2행 1열 듀플렉스계 스테인리스강(STS329FLD) 볼트접합부에 대한 구조적 성능을 조사하기 위한 실험적 연구를 수행하였다. 주요변수는 전단접합형태(일면전단과 이면전단)과 하중방향 연단거리이다. 종국파단형태는 전형적인 블록전단파단, 인장파단과 면외변형이 관찰되었다. 일면전단 접합부에서 면외변형발생으로 최대 20%까지 내력저하가 발생되었다. 실험최대내력은 현행설계기준 AISC/AISI/KBC, EC3와 AIJ 및 기존연구자에 의한 제안된식에 의한 예측내력과 비교하였다. 면외변형이 발생하지 않은 접합부에 대해서 실제 전단파단단면을 고려한 Clement & The의 식에 의한 예측내력이 실험내력에 가장 근접했고 면외변형을 동반한 접합부에 대해서는 면외변형을 고려해 제안한 Kim & Lim식에 의해서 과대평가하는 것으로 나타났다.
Recently, the use of duplex stainless steel which with a two-phase microstructure (equal mixture of ferrite and austenite) has been increasedin a variety of industrial fields due to higher strength leading to weight saving, greater corrosion resistance(particularly, stress corrosion cracking) andlower price. However, currently, stainless steels are not included in the structural materials of Korean Building Code and corresponding design standardsare not specified. In this paper, experimental studies have been performed to investigate the structural behaviors of duplex stainless steel (STS329FLD)bolted connection with two bolts for providing the design data. Main variables are shear connection type (single shear and double shear) and end distanceparallel to the direction of applied force. Fracture modes at the final step of test were classified into typical block shear fracture, tensile fracture andcurling. Curling occurrence in single shear connection led to ultimate strength drop by up to 20%. Test strengths were compared with those by currentdesign specifications such as AISC/AISI/KBC, EC3 and AIJ and proposed equations by existing studies. For specimens with no curling, Clement &Teh's equation considering the active shear plane provided a higher strength estimation accurancy and for specimens with curling, Kim & Lim's equationconsidering strength reduction by curling was also overly unconservative to predict the ultimate strength of curled connections.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles