Seismic capacity evaluation of existing reinforced concrete buildings strengthened with a novel prestressing steel frame system for increasing lateral strength

Authors
이강석
Issue Date
Nov-2023
Publisher
Elsevier BV
Keywords
Non-linear dynamic analysis; Prestressing steel frame; Pseudo-dynamic testing; Reinforced concrete; Seismic capacity evaluation; Seismic strengthening; Strength increasing method
Citation
Journal of Building Engineering, v.79, pp 1 - 24
Pages
24
Indexed
SCIE
SCOPUS
Journal Title
Journal of Building Engineering
Volume
79
Start Page
1
End Page
24
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/115506
DOI
10.1016/j.jobe.2023.107856
ISSN
2352-7102
2352-7102
Abstract
In this study, a new concept of seismic retrofit, the Prestressing Steel Frame (PSF) system, is proposed to improve and compensate for the weaknesses of the existing strength-enhancing seismic retrofit method. The PSF system, a construction method that maximizes the advantages of the H-shaped steel frame, innovatively improves the constructability and integrity of existing reinforced concrete (R/C) frames and reinforcement joints. This method is a type of typical strength-increasing reinforcement method that facilitates calculation of the required seismic reinforcement amount, and easily enhances the horizontal strength of shear collapse-type R/C buildings with non-seismic detailing. To review the seismic performance of the proposed PSF method, pseudo-dynamic tests were conducted on a real two-story frame based on an existing R/C building without seismic detailing, and seismic performance was evaluated in terms of load and displacement characteristics, seismic damage level, strength enhancement effect, and displacement control. In addition, based on the results of pseudo-dynamic testing, a hysteresis model was proposed to perform non-linear dynamic analysis of the seismically reinforced structure (twostory frame) with the PSF method. Non-linear dynamic analysis was performed based on the proposed hysteresis model, and the results were compared against that of pseudo-dynamic testing. For the commercialization of the method, non-linear dynamic analysis was conducted on the entire R/C building reinforced with PSF, and the effectiveness of seismic reinforcement was verified by comparing the seismic response load and displacement response before and after reinforcement. In the event of an earthquake with a maximum ground acceleration of 200 cm/s2, which is 2/3 of major earthquakes with a 2400-year recurrence interval stipulated in Korea Design Standard (KDS) 41, shear failure is expected for R/C buildings with non-seismic detailing, while small-scale damage is predicted for buildings reinforced with the PSF method. This shows that the PSF strengthening method is effective in minimizing earthquake damage.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher LEE, KANG SEOK photo

LEE, KANG SEOK
ERICA 공학대학 (MAJOR IN ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE