Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Novel Procedure for Automatic Registration between Cone-Beam Computed Tomography and Intraoral Scan Data Supported with 3D Segmentationopen access

Authors
Kim, Yoon-JiAhn, Jang-HoonLim, Hyun-KyoNguyen, Thong PhiJha, NayansiKim, AmiYoon, Jonghun
Issue Date
Nov-2023
Publisher
Multidisciplinary Digital Publishing Institute (MDPI)
Keywords
3D registration; cone-beam computed tomography; intraoral scan; orthodontics
Citation
Bioengineering, v.10, no.11, pp 1 - 15
Pages
15
Indexed
SCIE
SCOPUS
Journal Title
Bioengineering
Volume
10
Number
11
Start Page
1
End Page
15
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/116298
DOI
10.3390/bioengineering10111326
ISSN
2306-5354
2306-5354
Abstract
In contemporary practice, intraoral scans and cone-beam computed tomography (CBCT) are widely adopted techniques for tooth localization and the acquisition of comprehensive three-dimensional models. Despite their utility, each dataset presents inherent merits and limitations, prompting the pursuit of an amalgamated solution for optimization. Thus, this research introduces a novel 3D registration approach aimed at harmonizing these distinct datasets to offer a holistic perspective. In the pre-processing phase, a retrained Mask-RCNN is deployed on both sagittal and panoramic projections to partition upper and lower teeth from the encompassing CBCT raw data. Simultaneously, a chromatic classification model is proposed for segregating gingival tissue from tooth structures in intraoral scan data. Subsequently, the segregated datasets are aligned based on dental crowns, employing the robust RANSAC and ICP algorithms. To assess the proposed methodology’s efficacy, the Euclidean distance between corresponding points is statistically evaluated. Additionally, dental experts, including two orthodontists and an experienced general dentist, evaluate the clinical potential by measuring distances between landmarks on tooth surfaces. The computed error in corresponding point distances between intraoral scan data and CBCT data in the automatically registered datasets utilizing the proposed technique is quantified at 0.234 ± 0.019 mm, which is significantly below the 0.3 mm CBCT voxel size. Moreover, the average measurement discrepancy among expert-identified landmarks ranges from 0.368 to 1.079 mm, underscoring the promise of the proposed method. © 2023 by the authors.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Jong hun photo

Yoon, Jong hun
ERICA 공학대학 (DEPARTMENT OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE