dc.description.abstract | Since the converter transformer in the HVDC system is affected by both AC and DC voltages differently from the conventional converter transformer, a new isolation problem appears. As the DC voltage is applied to the valve winding of the converter transformer, the press board insulation on the valve side of the converter transformer must withstand the mixed AC voltage and DC voltage. In addition, high frequency harmonics are generated in the process of converting DC voltage to AC voltage through the converter transformer. High frequency AC voltage is mixed with DC voltage, eventually the mixed voltage can cause insulation breakdown in the press board. However, many studies have been conducted on the insulation characteristics of press boards under AC or DC voltage, but research on the insulation characteristics of press boards under AC-DC combined voltage are insufficient. Therefore, it is necessary to study the insulation characteristics of pressboard under AC-DC combined voltage. In this paper, frequency and ripple factor were selected to investigate the insulation characteristics of pressboard under high frequency and AC-DC combined voltage. Experiment results, confirmed that the dielectric strength decreased linearly as the ripple factor increased, and the breakdown voltage decreased as the frequency increased. Consequently, it has been analyzed that the valve-side insulation of the converter transformer is more affected by frequency and AC-DC combined voltage. | - |
dc.format.extent | 4 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | IEEE | - |
dc.title | Dielectric Breakdown Characteristics of Oil Impregnated Pressboard according to Frequency Change under AC-DC Combined Voltage | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1109/ICEPE-ST51904.2022.9756989 | - |
dc.identifier.scopusid | 2-s2.0-85129503748 | - |
dc.identifier.wosid | 000812317000084 | - |
dc.identifier.bibliographicCitation | 2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST), pp 410 - 413 | - |
dc.citation.title | 2022 6th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST) | - |
dc.citation.startPage | 410 | - |
dc.citation.endPage | 413 | - |
dc.type.docType | Proceedings Paper | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.subject.keywordAuthor | AC-DC combined voltage | - |
dc.subject.keywordAuthor | pressboard | - |
dc.subject.keywordAuthor | ripple factor | - |
dc.identifier.url | https://ieeexplore.ieee.org/document/9756989 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.