Assessment of Hydrazone Derivatives for Enhanced Steel Corrosion Resistance in 15 wt.% HCl Environments: A Dual Experimental and Theoretical Perspectiveopen access

Authors
El-khlifi, AbdelilahZouhair, Fatima ZahraeAl-Hadeethi, Mustafa R.Lgaz, HassaneLee, Han-SeungSalghi, RachidHammouti, BelkheirErramli, Hamid
Issue Date
Mar-2024
Publisher
Multidisciplinary Digital Publishing Institute (MDPI)
Keywords
computational method; corrosion inhibition; corrosion testing; density functional tight-binding; hydrazone; pipeline; steel
Citation
Molecules, v.29, no.5, pp 1 - 21
Pages
21
Indexed
SCIE
SCOPUS
Journal Title
Molecules
Volume
29
Number
5
Start Page
1
End Page
21
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/118331
DOI
10.3390/molecules29050985
ISSN
1420-3049
1420-3049
Abstract
This study evaluates the corrosion inhibition capabilities of two novel hydrazone derivatives, (E)-2-(5-methoxy-2-methyl-1H-indol-3-yl)-N′-(4-methylbenzylidene)acetohydrazide (MeHDZ) and (E)-N′-benzylidene-2-(5-methoxy-2-methyl-1H-indol-3-yl)acetohydrazide (HHDZ), on carbon steel in a 15 wt.% HCl solution. A comprehensive suite of analytical techniques, including gravimetric analysis, potentiodynamic polarization (PDP), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM), demonstrates their significant inhibition efficiency. At an optimal concentration of 5 × 10−3 mol/L, MeHDZ and HHDZ achieve remarkable inhibition efficiencies of 98% and 94%, respectively. EIS measurements reveal a dramatic reduction in effective double-layer capacitance (from 236.2 to 52.8 and 75.3 µF/cm2), strongly suggesting inhibitor adsorption on the steel surface. This effect is further corroborated by an increase in polarization resistance and a significant decrease in corrosion current density at optimal concentrations. Moreover, these inhibitors demonstrate sustained corrosion mitigation over extended exposure durations and maintain effectiveness even under elevated temperatures, highlighting their potential for diverse operational conditions. The adsorption process of these inhibitors aligns well with the Langmuir adsorption isotherm, implying physicochemical interactions at the carbon steel surface. Density functional tight-binding (DFTB) calculations and molecular dynamics simulations provide insights into the inhibitor-surface interaction mechanism, further elucidating the potential of these hydrazone derivatives as highly effective corrosion inhibitors in acidic environments. © 2024 by the authors.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lgaz, Hassane photo

Lgaz, Hassane
ERICA부총장 한양인재개발원 (ERICA 창의융합교육원)
Read more

Altmetrics

Total Views & Downloads

BROWSE