Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A dual-frequency colinear array for acoustic angiography in prostate cancer evaluation

Authors
Li, SiboKim, JinwookWang, ZhuochenKasoji, SandeepLindsey, Brooks D.Dayton, Paul A.Jiang, Xiaoning
Issue Date
Sep-2018
Publisher
Institute of Electrical and Electronics Engineers
Keywords
Harmonic analysis; in vivo; oncology; ultrasonic imaging; ultrasonic transducer arrays
Citation
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, v.65, no.12, pp 2418 - 2428
Pages
11
Indexed
SCI
SCIE
SCOPUS
Journal Title
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Volume
65
Number
12
Start Page
2418
End Page
2428
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/118821
DOI
10.1109/TUFFC.2018.2872911
ISSN
0885-3010
1525-8955
Abstract
Approximately 80% of men who reach 80 years of age will have some form of prostate cancer. The challenge remains to differentiate benign and malignant lesions. Based on recent research, acoustic angiography, a novel contrast-enhanced ultrasound imaging technique, can provide high-resolution visualization of tissue microvasculature and has demonstrated the ability to differentiate vascular characteristics between healthy and tumor tissue in preclinical studies. We hypothesize that transrectal acoustic angiography may enhance the assessment of prostate cancer. In this paper, we describe the development of a dual frequency, dual-layer colinear array transducer for transrectal acoustic angiography. The probe consists of 64 transmitting (TX) elements with a center frequency of 3 MHz and 128 receiving (RX) elements with a center frequency of 15 MHz. The dimensions of the array are 18 mm in azimuth and 9 mm in elevation. The pitch is 280 μm for TX elements and 140 μm for RX elements. Pulse-echo tests of TX/RX elements and aperture acoustic field measurements were conducted, and both results were compared with the simulation results. Realtime contrast imaging was performed using a Verasonics system and a tissue-mimicking phantom. Nonlinear acoustic responses from microbubble contrast agents at a depth of 35 mm were clearly observed. In vivo imaging in a rodent model demonstrated the ability to detect individual vessels underneath the skin. These results indicate the potential use of the array described herein for acoustic angiography imaging of prostate tumor and identification of regions of neovascularization for the guidance of prostate biopsies.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE