Microfluidic chip with integrated separation, mixing, and concentration operations for rapid and sensitive bacterial detection utilizing synthetic inorganic antibodies

Authors
Nam, Young-HoLee, SinLee, Seung-KiKim, Jong -HoPark, Jae-Hyoung
Issue Date
Apr-2024
Publisher
Elsevier BV
Keywords
Microfluidics; Bacteria detection; Particle separation; Mixer; Membrane filter
Citation
Sensors and Actuators, B: Chemical, v.404, pp 1 - 11
Pages
11
Indexed
SCIE
SCOPUS
Journal Title
Sensors and Actuators, B: Chemical
Volume
404
Start Page
1
End Page
11
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/119451
DOI
10.1016/j.snb.2023.135202
ISSN
0925-4005
Abstract
In this paper, we presented a microfluidic chip that integrates bacterial separation, mixing, and concentration solely through fluid dynamics. Size-based bacterial separation was achieved through Dean flow and inertial focusing by harnessing the attributes of a spiral-shaped fluidic channel. Furthermore, Dean flow was capitalized upon to enable the mixing of bacteria with the detection substance, complemented by the integration of PDMS membrane filter for bacterial concentration, all unified within the chip architecture. The performance of individual components was validated using E. coli. In the separation experiment between 4.1 mu m particles and E. coli, a separation efficiency of 87.07 +/- 2.21% was measured for E. coli, and the mixer demonstrated a mixing efficiency of 92.8% at 30 mu L/min flow rate. Concentrating E. coli through the filter for 30 min yielded an average loss rate of 7.47%. Moreover, the proposed microfluidic device was applied for bacterial detection using both our inhouse-developed inorganic synthetic antibodies and commercially available fluorescent antibodies. Real-time optical measurements demonstrated the potential of the chip for cost-effective, rapid, and sensitive bacterial detection. The versatility of the chip was substantiated by its successful implementation for the E. coli detection at a concentration of 102 CFU/mL in spiked urine samples.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MATERIALS SCIENCE AND CHEMICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Jong-Ho photo

Kim, Jong-Ho
ERICA 공학대학 (DEPARTMENT OF MATERIALS SCIENCE AND CHEMICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE