Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of Anaerobic Co-Digestion of Food Waste and Livestock Manure at Various Mixing Ratios under Mesophilic and Thermophilic Temperaturesopen access

Authors
Lee, WonbaeKim, YoungoKim, HoKim, Moonil
Issue Date
Sep-2024
Publisher
Multidisciplinary Digital Publishing Institute (MDPI)
Keywords
anaerobic co-digestion; anaerobic toxicity assay; biochemical methane potential; optimization; organic waste
Citation
Sustainability (Switzerland), v.16, no.17, pp 1 - 17
Pages
17
Indexed
SCIE
SSCI
SCOPUS
Journal Title
Sustainability (Switzerland)
Volume
16
Number
17
Start Page
1
End Page
17
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/120548
DOI
10.3390/su16177653
ISSN
2071-1050
2071-1050
Abstract
In this study, the optimum mixing ratio of food waste (FW) and livestock manure (LM) was investigated to improve the methane yield efficiency and prohibit the inhibition factors (organic loading rate and NH4+) from inhibiting the anaerobic co-digestion of FW and LM under mesophilic and thermophilic conditions. The research involved the following: (I) the analysis of the characteristics of FW and LM, (II) the evaluation of the potential and toxicity of the anaerobic digestion of I have confirmed that there is no problem. FW and LM using the biochemical methane potential (BMP) and anaerobic toxicity assay (ATA) tests, (III) the evaluation of the anaerobic co-digestion of FW and LM using the BMP test, and (IV) the evaluation of the optimum mixing ratio using mathematical modeling. The characteristics of FW and LM were analyzed to evaluate the theoretical methane potential and inhibition factor. The BMP test was carried out to evaluate the concentration of the biodegradable organic matter, biogas production rate, and methane yield. The ATA test was carried out to evaluate the impact of the inhibition concentration. Ultimately, mathematical models, such as a first-order reaction and a modified Gompertz model, were implemented to evaluate the optimum mixing ratio for the anaerobic co-digestion of FW and LM. FW had a higher concentration of degradable organic matter than LM. The initial operational parameters of the anaerobic digestion were determined to be appropriate at an organic matter concentration of less than 2.5 g/L and a TN concentration of 2,000 mg/L. In conclusion, as a result of evaluation through mathematical models, it was determined that anaerobic microorganisms were more sensitive to inhibitory factors under the thermophilic condition than under the mesophilic condition, and the optimum mixing ratio of FW to LM was 5:1 (vol:vol) based on kinetic results (k: 0.080; Bu: 0.23 L CH4/g VSadded; P: 100.84 mL; Rm: 10.23 mL/day; λ: 1.44 days). © 2024 by the authors.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Moon il photo

Kim, Moon il
ERICA 공학대학 (DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE