Smart carbon fiber reinforced plastic tubes with electromechanical structural health self-monitoring system
- Authors
- Roh, Hyung Doh; Lee, Dahun; Park, Young-Bin
- Issue Date
- Jan-2025
- Publisher
- Elsevier Ltd
- Keywords
- Finite element analysis; Polymer-matrix composites (PMCs); Smart composite
- Citation
- Engineering Structures, v.322, pp 1 - 12
- Pages
- 12
- Indexed
- SCIE
SCOPUS
- Journal Title
- Engineering Structures
- Volume
- 322
- Start Page
- 1
- End Page
- 12
- URI
- https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/120723
- DOI
- 10.1016/j.engstruct.2024.118853
- ISSN
- 0141-0296
1873-7323
- Abstract
- Carbon fiber-reinforced plastics (CFRPs), are utilized in the various mobilities owing to their superior specific structural rigidity. However, the studies for the structural health monitoring (SHM) of a tubular CFRP are relatively limited compared to its market share although it is directly related to the structural duties. Thus, this study investigated structural health self-monitoring (SHSm) of tubular CFRPs by monitoring their electrical resistances simultaneously. Multiple electrodes monitored electrical resistances of the CFRP tubes in terms of their mechanical deformation realizing condition-based SHM without any sensors. The proposed self-monitoring technology enabled not only local but also global deformation even after the mechanical fractures. Furthermore, the proposed self-monitoring method was comparatively analyzed and verified with corresponding mechanics and finite element analysis. Therefore, real-time SHSm technology for tubular CFRPs with various fiber stacking configurations was realised in this study covering all the deformation types over the whole structures. © 2024
- Files in This Item
-
Go to Link
- Appears in
Collections - COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles