Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Colorimetric and Photothermal Creatinine Determination Using MoS<sub>2</sub> Nanosheet Cocatalyst with Cu<SUP>2+</SUP>/Creatinine Complexes

Authors
Jeon, Sung MinLee, Han BeenHa, Chang HyeonKim, Do HyeonSeong, Gi Hun
Issue Date
Nov-2024
Publisher
American Chemical Society
Keywords
creatinine; molybdenum disulfide nanosheet; cocatalyst; colorimetric; photothermal; dual-mode detection
Citation
ACS Applied Nano Materials, v.8, no.1, pp 1 - 10
Pages
10
Indexed
SCIE
SCOPUS
Journal Title
ACS Applied Nano Materials
Volume
8
Number
1
Start Page
1
End Page
10
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/121200
DOI
10.1021/acsanm.4c05373
ISSN
2574-0970
2574-0970
Abstract
Creatinine (CRE) has been considered to be a critical biomarker for assessing renal dysfunction and muscular metabolism. In this study, we developed a dual-mode colorimetric and photothermal CRE sensor for selective detection of CRE using gum arabic-treated molybdenum disulfide with copper ions (GA-MoS2@Cu2+). In the system, GA-MoS2 nanosheets can be used as a cocatalyst in the copper Fenton-like reaction. Moreover, in the presence of CRE, the copper Fenton-like reaction can be accelerated through cocatalysis of GA-MoS2 nanosheets, which increases the electron transfer capacity of the system. This facilitates the production of larger amounts of reactive oxygen species (ROS) and promotes the oxidation of 3,3 ',5,5 '-tetramethylbenzidine (TMB). The catalytic activity of GA-MoS2@Cu2+/CRE increases with higher concentrations of CRE. The oxidized TMB (TMBox) served as a signal for the colorimetric and photothermal sensors due to its visible and near-infrared (NIR) light absorbance. Heat was generated in proportion to the concentration of CRE when light from an NIR laser was absorbed by TMBox in the reaction solution. The proposed sensor demonstrated linear detection ranges of 0.5-500 and 5-500 mu M, with limits of detection (LODs) of 0.19 and 3.30 mu M, respectively, with a very fast assay time. In addition, the applicability and viability of the sensor were successfully demonstrated in human serum tests with recoveries of 95-108%. These results demonstrate the capability and feasibility of the sensors, with the advantages of high sensitivity, selectivity, cost-effectiveness, and portability for use in clinical detection and point-of-care testing.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF BIONANO ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seong, Gi Hun photo

Seong, Gi Hun
ERICA 첨단융합대학 (ERICA 바이오나노공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE