Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Microstructure, Mechanical Properties and Corrosion Performance of Laser-Welded NiTi Shape Memory Alloy in Simulated Body Fluidopen access

Authors
Kannan, A. RajeshShanmugam, N. SivaRajkumar, V.Vishnukumar, M.Channabasavanna, S. G.Oh, JunhoDat, Than Trong KhanhYoon, Jonghun
Issue Date
Oct-2024
Publisher
MDPI Open Access Publishing
Keywords
shape memory alloy; NiTi; laser-welding; microstructure; corrosion; simulated body fluid
Citation
Materials, v.17, no.19, pp 1 - 19
Pages
19
Indexed
SCIE
SCOPUS
Journal Title
Materials
Volume
17
Number
19
Start Page
1
End Page
19
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/121421
DOI
10.3390/ma17194801
ISSN
1996-1944
1996-1944
Abstract
Laser-welding is a promising technique for welding NiTi shape memory alloys with acceptable tensile strength and comparable corrosion performance for biomedical applications. The microstructural characteristics and localized corrosion behavior of NiTi alloys in a simulated body fluid (SBF) environment are evaluated. A microstructural examination indicated the presence of fine and equiaxed grains with a B2 austenite phase in the base metal (BM), while the weld metal (WM) had a coarse dendritic microstructure with intermetallic precipitates including Ti2Ni and Ni4Ti3. The hardness decreased from the BM to the WM, and the average hardness for the BM was 352 +/- 5 HV, while it ranged between 275 and 307 HV and 265 and 287 HV for the HAZ and WM, respectively. Uni-axial tensile tests revealed a substantial decrease in the tensile strength of NiTi WM (481 +/- 19 MPa), with a reduced joint efficiency of 34%. The localized corrosion performance of NiTi BM was superior to the WM, with electrochemical test responses indicating a pitting potential and low corrosion rate in SBF environments. The corrosion rate of the NiTi BM and WM was 0.048 +/- 0.0018 mils per year (mpy) and 0.41 +/- 0.019 mpy, respectively. During welding, NiTi's strength and biocompatibility properties changed due to the alteration in microstructure and formation of intermetallic phases as a result of Ti enrichment. The performance and safety of welded medical devices may be impacted during welding, and it is essential to preserve the biocompatibility of NiTi components for biomedical applications.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Junho photo

Oh, Junho
ERICA 공학대학 (DEPARTMENT OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE