Local Entropy Generation Analysis of the Counter-Flow Dew-Point Evaporative Coolers
- Authors
- Yang, Cheng; Chen, Haonan; Takahiko Miyazaki; Kim, Young-Deuk; Khargotra, Rohit; Thu, Kyaw
- Issue Date
- May-2024
- Publisher
- The American Society of Mechanical Engineers(ASME)
- Keywords
- air conditioning; cooling; dew-point evaporative cooling; efficiency; energy; heat transfer; indoor air quality; local entropy generation; mass transfer
- Citation
- Journal of Engineering for Sustainable Buildings and Cities, v.5, no.2, pp 1 - 14
- Pages
- 14
- Indexed
- SCOPUS
- Journal Title
- Journal of Engineering for Sustainable Buildings and Cities
- Volume
- 5
- Number
- 2
- Start Page
- 1
- End Page
- 14
- URI
- https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/122218
- DOI
- 10.1115/1.4065740
- ISSN
- 2642-6641
2642-6625
- Abstract
- A comfortable indoor working circumstance can be accomplished by a ventilation and air conditioning system. There are several factors influencing the quality of indoor air, with the insufficiency of ventilation accounting for over 50% of the overall considerations. While traditional air conditioner is able to fulfill the needs of ventilation and indoor temperature control, low-efficiency and high energy consumption no longer align with the current sustainable and energy-efficiency goals. Thus, the development of energy-saving and high-efficiency air conditioning systems is crucial for realizing green and efficient building practices. Evaporative cooling technology, specifically dew-point evaporative cooling, has garnered extensive attention as an efficient cooling method and a candidate for environmentally friendly and high-performance alternatives to traditional air conditioning systems. This article investigates the thermodynamic losses involved in a dew-point evaporative cooling system using the counter-flow design. Detailed mathematical models for the evaporative cooler along with the entropy generation in the channels are developed. The model facilitates calculations of (1) the entropy generation distribution in different layers within the system and (2) the entropy generation of each layer and the whole system under various input conditions. Approaching the system from the second law of thermodynamics perspective, this model serves as a guide for selecting the optimal operating conditions, thus promoting the widespread application and commercialization of dew-point evaporative cooling systems with the counter-flow structure.
- Files in This Item
-
Go to Link
- Appears in
Collections - COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.