Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

An ultra-high-performance liquid chromatography-tandem mass spectrometric method for the determination of hederacoside C, a drug candidate for respiratory disorder, in rat plasma

Authors
Rehman, Shaheed UrChoi, Min SunKim, In SookKim, Seung HyunYoo, Hye Hyun
Issue Date
Sep-2016
Publisher
ELSEVIER SCIENCE BV
Keywords
Hederacoside C; Hedera helix; UPLC-MS/MS; Plasma; Pharmacokinetics
Citation
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, v.129, pp.90 - 95
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Volume
129
Start Page
90
End Page
95
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/13046
DOI
10.1016/j.jpba.2016.06.039
ISSN
0731-7085
Abstract
Hederacoside C is a principal bioactive pharmaceutical ingredient of Hedera helix leaf extracts. H. helix extracts have long been used in folk medicine for the treatment of respiratory disorders. Currently, hederacoside C is investigated as a promising candidate for the treatment of respiratory diseases. In this study, an accurate, sensitive, rapid, and reliable bioanalytical method was developed for the determination of hederacoside C in rat plasma using ultra high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). For sample preparation, plasma proteins were precipitated with 0.1% acetic acid in acetonitrile. Waters UPLC BEH C-18 (2.1 mm I.D. x 100 mm, 1.7 mu m) column was used for chromatographic separation. A gradient elution of mobile phases consisting of 0.02% acetic acid in distilled water (solvent A) and 0.02% acetic acid in acetonitrile (solvent B) was used at a flow rate of 0.3 mL/min. The multiple reaction monitoring (MRM) mode was used for mass spectrometric detection; the MRM transitions were m/z 1219.7 -> m/z 469.2 for hederacoside C and m/z 1108.3 -> m/z 221.2 for ginsenoside Rb1 (internal standard) in the negative ionization mode. A calibration curve was constructed in the range of 10-1000 ng/mL. The intra- and inter-day precision and accuracy were within 5%. The developed UPLC-MS/MS method was successfully applied in a pharmacokinetic study of hederacoside C in rats. Hederacoside C was quickly but inadequately absorbed from the gastrointestinal tract of rats resulting in extremely low bioavailability and relatively slow clearance. (C) 2016 Elsevier B.V. All rights reserved.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF PHARMACY > DEPARTMENT OF PHARMACY > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Hye Hyun photo

Yoo, Hye Hyun
COLLEGE OF PHARMACY (DEPARTMENT OF PHARMACY)
Read more

Altmetrics

Total Views & Downloads

BROWSE