Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Influence of non-uniform intensity distribution of deformed pellicle for N7 patterning

Full metadata record
DC Field Value Language
dc.contributor.authorKim, In seon-
dc.contributor.authorKim, Guk jin-
dc.contributor.authorYeung, Michael-
dc.contributor.authorBarouch, Eytan-
dc.contributor.authorKim, Min su-
dc.contributor.authorPark, Jin-Goo-
dc.contributor.authorOh, Hye keun-
dc.date.accessioned2021-06-22T18:10:00Z-
dc.date.available2021-06-22T18:10:00Z-
dc.date.created2021-01-22-
dc.date.issued2016-09-
dc.identifier.issn0277-786X-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/15658-
dc.description.abstractFor protecting mask from debris, EUV pellicle is considered as a most effective solution. EUV pellicle can avoid contamination on mask by covering mask. Usage of EUV pellicle can reduce mask damage caused by contamination but the pellicle involves transmission loss due to absorption of EUV light. To get high transmission, pellicle made with thin thickness but it can be deformed easily due to weak structure. Deformation of pellicle such as wrinkle leads transmission non-uniformity and transmission non-uniformity will involve CD non-uniformity. For real-application at lithography process, the optical study of deformed pellicle is required to avoid degradation of CD uniformity. In this paper, we discuss transmission non-uniformity with various off-axis-illumination (OAI) conditions. Then we studied CD nonuniformity caused by wrinkled pellicle with various patterns. By increasing spatial coherence, transmission nonuniformity is decrease at small wrinkle region. However, transmission non-uniformity variation is independent with illumination conditions at large wrinkle which has large period. Not only wrinkled pellicle imaging but also CD variation caused by non-uniform transmission is also dependent on illumination conditions. In contrast with transmission nonuniformity, CD non-uniformity with high coherent light is smaller than the result with low coherent light. With all of results, we find that the allowable local tilt angle is varied with wrinkle size and illumination conditions and smallest size of allowable local tilt angle is about 250 mrad for both illuminations. © 2016 SPIE.-
dc.language영어-
dc.language.isoen-
dc.publisherSPIE-
dc.titleInfluence of non-uniform intensity distribution of deformed pellicle for N7 patterning-
dc.typeArticle-
dc.contributor.affiliatedAuthorPark, Jin-Goo-
dc.contributor.affiliatedAuthorOh, Hye keun-
dc.identifier.doi10.1117/12.2242999-
dc.identifier.scopusid2-s2.0-85006974002-
dc.identifier.wosid000389775700009-
dc.identifier.bibliographicCitationProceedings of SPIE - The International Society for Optical Engineering, v.9985-
dc.relation.isPartOfProceedings of SPIE - The International Society for Optical Engineering-
dc.citation.titleProceedings of SPIE - The International Society for Optical Engineering-
dc.citation.volume9985-
dc.type.rimsART-
dc.type.docTypeConference Paper-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOptics-
dc.relation.journalWebOfScienceCategoryOptics-
dc.subject.keywordPlusCoherent light-
dc.subject.keywordPlusDeformation-
dc.subject.keywordPlusExtreme ultraviolet lithography-
dc.subject.keywordPlusPhotomasks-
dc.subject.keywordPlusCD non-uniformity-
dc.subject.keywordPlusCD Uniformity-
dc.subject.keywordPlusEffective solution-
dc.subject.keywordPlusIllumination conditions-
dc.subject.keywordPlusLithography process-
dc.subject.keywordPlusLow-coherent lights-
dc.subject.keywordPlusOff axis illumination-
dc.subject.keywordPlusPellicle-
dc.subject.keywordPlusLithography-
dc.subject.keywordAuthorCD uniformity-
dc.subject.keywordAuthorEUV lithography-
dc.subject.keywordAuthorPellicle-
dc.subject.keywordAuthorPellicle deformation-
dc.identifier.urlhttps://www.spiedigitallibrary.org/conference-proceedings-of-spie/9985/1/Influence-of-non-uniform-intensity-distribution-of-deformed-pellicle-for/10.1117/12.2242999.short-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF SCIENCE AND CONVERGENCE TECHNOLOGY > DEPARTMENT OF APPLIED PHYSICS > 1. Journal Articles
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MATERIALS SCIENCE AND CHEMICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jin Goo photo

Park, Jin Goo
ERICA 공학대학 (DEPARTMENT OF MATERIALS SCIENCE AND CHEMICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE