Feasibility analysis of a novel hybrid-type superconducting circuit breaker in multi-terminal HVDC networks

Authors
Khan, Umer AmirLee, Jong-GeonSeo, In-JinAmir, FaisalLee, Bang-Wook
Issue Date
Nov-2015
Publisher
Elsevier BV
Keywords
Multi-terminal HVDC (MTDC); HVDC circuit breaker (DCCB); Superconducting fault current limiter (SFCL); DC interruption; Bi-directional current; IGBT valves
Citation
Physica C: Superconductivity and its Applications, v.518, pp.154 - 158
Indexed
SCIE
SCOPUS
Journal Title
Physica C: Superconductivity and its Applications
Volume
518
Start Page
154
End Page
158
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/16516
DOI
10.1016/j.physc.2015.03.015
ISSN
0921-4534
Abstract
Voltage source converter-based HVDC systems (VSC-HVDC) are a better alternative than conventional thyristor-based HVDC systems, especially for developing multi-terminal HVDC systems (MTDC). However, one of the key obstacles in developing MTDC is the absence of an adequate protection system that can quickly detect faults, locate the faulty line and trip the HVDC circuit breakers (DCCBs) to interrupt the DC fault current. In this paper, a novel hybrid-type superconducting circuit breaker (SDCCB) is proposed and feasibility analyses of its application in MTDC are presented. The SDCCB has a superconducting fault current limiter (SFCL) located in the main current path to limit fault currents until the final trip signal is received. After the trip signal the IGBT located in the main line commutates the current into a parallel line where DC current is forced to zero by the combination of IGBTs and surge arresters. Fault simulations for three-, four- and five-terminal MTDC were performed and SDCCB performance was evaluated in these MTDC. Passive current limitation by SFCL caused a significant reduction of fault current interruption stress in the SDCCB. It was observed that the DC current could change direction in MTDC after a fault and the SDCCB was modified to break the DC current in both the forward and reverse directions. The simulation results suggest that the proposed SDCCB could successfully suppress the DC fault current, cause a timely interruption, and isolate the faulty HVDC line in MTDC. (C) 2015 Elsevier B.V. All rights reserved.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Bang Wook photo

Lee, Bang Wook
ERICA 공학대학 (SCHOOL OF ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE