Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Immunoassay of cardiac biomarkers using a photodiode array biochip

Authors
Han, Kwi NamLe, Thanh-HaiPham, Xuan-HungBuu-Chau Huynh-NguyenKim, Ji HyeKo, EunaKwon, Ho TaikSeong, Gi Hun
Issue Date
Feb-2015
Publisher
ELSEVIER SCIENCE SA
Keywords
Photodiode array; Immunoassay; Myoglobin; Cardiac troponin I; Gold nanoparticles; Silver enhancement
Citation
SENSORS AND ACTUATORS B-CHEMICAL, v.207, no.PartA, pp 470 - 476
Pages
7
Indexed
SCI
SCIE
SCOPUS
Journal Title
SENSORS AND ACTUATORS B-CHEMICAL
Volume
207
Number
PartA
Start Page
470
End Page
476
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/18864
DOI
10.1016/j.snb.2014.10.014
ISSN
0925-4005
Abstract
We present a photodiode array (PDA) biochip using a bipolar semiconductor that can detect cardiacbio markers such as myoglobin (Myo) and cardiac troponin I (cTnI) with sensitivity and a large dynamic range. The PDA chip, which consists of a 12 x 12 array of photodiodes with each photodiode having a diameter of 200 mu m, acts as both a support for antibody immobilization and as a two-dimensional detector. In addition, the PDA chip system does not require complicated optical components and can be miniaturized, resulting in the construction of a portable microarray chip system. An immune-sandwich assay was carried out on the PDA chip, followed by gold nanoparticle-promoted silver enhancement for the improvement of sensitivity. The deposited silver metals blocked the light irradiated from light-emitting diodes, resulting in a decrease of the output voltage corresponding to the produced photocurrent. The decreased voltage was directly proportional to the concentrations of target antigens present in the sample solution, allowing the specific detection and the quantitative analysis of the cardiac biomarkers. The linear ranges of quantification of Myo and cTnI were from 10 to 10(4)ng/mL (R-2= 0.998, n = 3) and from 10 to 10(5)pg/mL (R-2=0.992, n=3), respectively. The detection limits of Myo and cTnI were determined to be 2.2 ng/mL and 4.0 pg/mL, respectively, which are lower than the clinical cutoff levels (Myo:70-200 ng/ mL; cTnI: 10-100 pg/mL). (C) 2014 Elsevier B. V. All rights reserved.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF BIONANO ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seong, Gi Hun photo

Seong, Gi Hun
ERICA 공학대학 (DEPARTMENT OF BIONANO ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE