DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hua, Yufeng | - |
dc.contributor.author | Oh, Je hoon | - |
dc.contributor.author | Kim, Yong bae | - |
dc.date.accessioned | 2021-06-22T21:02:53Z | - |
dc.date.available | 2021-06-22T21:02:53Z | - |
dc.date.created | 2021-01-22 | - |
dc.date.issued | 2015-09 | - |
dc.identifier.issn | 0513-5796 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/19703 | - |
dc.description.abstract | Purpose: The purpose of this study is to explore the influence of segmentation of the upstream and downstream parent artery and hemodynamic boundary conditions (BCs) on the evaluated hemodynamic factors for the computational fluid dynamics (CFD) analysis of intracranial aneurysms. Materials and Methods: Three dimensional patient-specific aneurysm models were analyzed by applying various combinations of inlet and outlet BCs. Hemodynamic factors such as velocity pattern, streamline, wall shear stress, and oscillatory shear index at the systolic time were visualized and compared among the different cases. Results: Hemodynamic factors were significantly affected by the inlet BCs while there was little influence of the outlet BCs. When the inlet length was relatively short, different inlet BCs showed different hemodynamic factors and the calculated hemodynamic factors were also dependent on the inlet length. However, when the inlet length (L) was long enough (L>20D, where D is the diameterof inlet section), the hemodynamic factors became similar regardless of the inlet BCs and lengths. The error due to differentinlet BCs was negligible. The effect of the outlet length on the hemodynamic factors was similar to that of the inlet length. Conclusion: Simulated hemodynamic factors are highly sensitive to inlet BCs and upstream parent artery segmentation. The resultsof this work can provide an insight into how to build models and to apply BCs for more accurate estimation of hemodynamic factors from CFD simulations of intracranial aneurysms. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | 연세대학교의과대학 | - |
dc.title | Influence of Parent Artery Segmentation and Boundary Conditions on Hemodynamic Characteristics of Intracranial Aneurysms | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Oh, Je hoon | - |
dc.identifier.doi | 10.3349/ymj.2015.56.5.1328 | - |
dc.identifier.scopusid | 2-s2.0-84938853606 | - |
dc.identifier.wosid | 000359886200021 | - |
dc.identifier.bibliographicCitation | Yonsei Medical Journal, v.56, no.5, pp.1328 - 1337 | - |
dc.relation.isPartOf | Yonsei Medical Journal | - |
dc.citation.title | Yonsei Medical Journal | - |
dc.citation.volume | 56 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 1328 | - |
dc.citation.endPage | 1337 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002022012 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | General & Internal Medicine | - |
dc.relation.journalWebOfScienceCategory | Medicine, General & Internal | - |
dc.subject.keywordPlus | COMPUTATIONAL FLUID-DYNAMICSWALL SHEAR-STRESSCEREBRAL ANEURYSMSFLOW DYNAMICSRISK-FACTORSBLOOD-FLOWRUPTUREMODELSENSITIVITYSIMULATION | - |
dc.subject.keywordAuthor | Intracranial aneurysms | - |
dc.subject.keywordAuthor | hemodynamic factors | - |
dc.subject.keywordAuthor | parent artery segmentation | - |
dc.subject.keywordAuthor | boundary conditions | - |
dc.subject.keywordAuthor | computational fluid dynamics | - |
dc.identifier.url | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002022012 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.