Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

레진강화형 글래스아이오노머 바니쉬를 이용한 상아세관의 폐쇄 평가: 상아세관액 흐름의 실시간 측정 및 주사전자현미경 관찰Evaluation of dentinal tubule occlusion by RMGI (resin-modified glass ionomer) varnish: real-time measurement of dentinal fluid flow and SEM

Other Titles
Evaluation of dentinal tubule occlusion by RMGI (resin-modified glass ionomer) varnish: real-time measurement of dentinal fluid flow and SEM
Authors
김민호KIM RYAN JIN YOUNG(김진영)임범순최낙삼이인복
Issue Date
Mar-2015
Publisher
대한치과재료학회
Keywords
dentinal fluid flow; dentinal tubule occlusion; real-time measurement; RMGI varnish; SEM
Citation
대한치과재료학회지, v.42, no.1, pp.57 - 63
Indexed
KCI
Journal Title
대한치과재료학회지
Volume
42
Number
1
Start Page
57
End Page
63
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/20159
DOI
10.14815/kjdm.2015.42.1.57
ISSN
2384-4434
Abstract
The purpose of this study was to compare the occlusive effect of a resin-modified glass ionomer (RMGI) varnish and an oxalate-based desensitizing agent on exposed dentin by evaluating the flow dynamic of dentinal fluid and SEM evaluation of the dentin surface after treatment. Sixteen caries- and restoration-free extracted molars were fixed to slide glasses after horizontally sectioning the roots at 5 mm below the cemento-enamel junction (CEJ). The prepared specimen was connected to a fluid flow measuring device (nano-Flow), and verified no fluid leakage. A V-shaped cavity was prepared at the CEJ to expose the dentin surface, which was then acid-etched, washed, and blot dried. The surface was treated either with an RMGI (Clinpro XT varnish) or an oxalate-based desensitizing agent (SuperSeal) (n=8). A real-time fluid flow was measured throughout the procedures. The fluid flow rates before and after each treatment were evaluated, and the surfaces of the treated dentinal tubules were also examined with SEM. A significant reduction in the rate of fluid flow was observed after treatment in both groups (p<0.05). Clinpro XT varnish exhibited a greater reduction in the fluid flow rate than SuperSeal (p<0.05). SEM evaluation revealed that the size of dentinal tubules was reduced as a result of the deposition of RMGI and oxalate crystals in Clinpro XT varnish and SuperSeal, respectively. Both agents reduced the fluid flow rate, with Clinpro XT varnish being more effective.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE