Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of the energy performance of a net zero energy building in a hot and humid climate

Authors
Shin, MinjaeBaltazar, Juan-CarlosHaberl, Jeff S.Frazier, EdwinLynn, Bobby
Issue Date
Dec-2019
Publisher
Elsevier Ltd
Keywords
Building energy simulation; Net zero energy building (NZEB); Regression analysis; Solar photovoltaic (PV) system; Variable refrigerant flow (VRF) system
Citation
Energy and Buildings, v.204, pp.1 - 15
Indexed
SCIE
SCOPUS
Journal Title
Energy and Buildings
Volume
204
Start Page
1
End Page
15
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/2200
DOI
10.1016/j.enbuild.2019.109531
ISSN
0378-7788
Abstract
In the past 20 years, the U.S. Army has made significant progress in making their facilities more energy efficient. Currently, the Army is required by law to eliminate fossil fuel use in new and renovated facilities by 2030 and to reduce overall facility energy usage 30% by 2030. As part of this on-going energy efficiency effort, the U.S. Army has designed and constructed a Net Zero Energy Building (NZEB) at the Fort Hood army base in Texas, which is currently being tested as a prototype. In order to achieve net zero performance and reduce the energy demand, several low-energy building technologies were designed and built including high-efficiency heating, ventilation, and air conditioning (HVAC) system, a high-performance building envelope, energy efficient lighting and a solar PV system. This paper presents the results of an evaluation of the net zero energy performance of the office building at the Fort Hood army base using measured data. The analysis methods applied to the building include: an un-adjusted, measured energy use comparison of both portions of the building; a weather-normalized, change-point linear regression to estimate annual energy savings; and calibrated building energy simulations with thermostat schedules and occupancy conditions of both portions in the building. The results show savings of 37–50% for the renovated portion of the building (i.e., NZEB) compared to the un-renovated portion depending on the method of analysis.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Minjae photo

Shin, Minjae
ERICA 공학대학 (MAJOR IN ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE