콘크리트 전류량에 따른 콘크리트 내 염화물 이온 침출에 관한 연구Research on Chloride Ion Leaching from Concrete Depending on Current Amount
- Other Titles
- Research on Chloride Ion Leaching from Concrete Depending on Current Amount
- Authors
- 황준필; 홍성인; 백승우; 안기용
- Issue Date
- May-2014
- Publisher
- 한국콘크리트학회
- Citation
- 2014 한국콘크리트학회 봄 학술대회, v.26, no.1, pp 187 - 188
- Pages
- 2
- Indexed
- OTHER
- Journal Title
- 2014 한국콘크리트학회 봄 학술대회
- Volume
- 26
- Number
- 1
- Start Page
- 187
- End Page
- 188
- URI
- https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/22896
- Abstract
- The present study, the effect of electrochemical treatment was assessed in terms of chloride transport. For the electrochemical chloride extraction analysis, direct current was applied for 4weeks ranged 250, 500, 750 mA/m2 . As a result, amount of current varies depending on the quantity of chloride ions extraction, which is corrosion resistance of concrete influence on the effect. 본 연구에서는 전기방식의 부식방식 효과의 분석을 위하여 염화물이동에 대한 시험을 실시하였다. 탈염기법을 적용하기 위하여 직류전류 250, 500, 750 mA/m2 를 4주간 공급하였으며, 전류량에 따라 염화물이온 침출량은 다르며, 이는 콘크리트의 부식방식 효과에 영향을 미치는 것으로 판단된다.