Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Sodium Phosphate Post-treatment on Al Coating: Morphological and Corrosion Study

Authors
Jeong, Hwa-RangLee, Han-SeungJalalzai, PalwashaKwon, Seung-JunSingh, Jitendra KumarHussain, Raja RizwanAlyousef, RayedAlabduljabbar, HishamAslam, Fahid
Issue Date
Oct-2019
Publisher
SPRINGER
Keywords
arc thermal spraying; coating; corrosion; electrochemical impedance spectroscopy; scanning electron microscopy; x-ray diffraction
Citation
JOURNAL OF THERMAL SPRAY TECHNOLOGY, v.28, no.7, pp 1511 - 1531
Pages
21
Indexed
SCI
SCIE
SCOPUS
Journal Title
JOURNAL OF THERMAL SPRAY TECHNOLOGY
Volume
28
Number
7
Start Page
1511
End Page
1531
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/2309
DOI
10.1007/s11666-019-00921-w
ISSN
1059-9630
1544-1016
Abstract
The coatings deposited by arc thermal spraying process possess defects and pores within the coating, which must be filled using a proper pore sealing agent. In the present study, we have deposited an Al coating on a steel substrate using arc thermal spraying. Post-treatment with different concentrations of sodium phosphate monobasic (NaH2PO4) salt solution was then carried out to fill the pores in the Al coating. The scanning electron microscopy results show that NaH2PO4 (SP) at 0.5 M concentration significantly reduces the porosity. When the concentration of NaH2PO4 is less than 0.5 M, the coating contains some pores and defects, whereas post-treatment with 1 M NaH2PO4 leads to the formation of a brittle film with wide cracks on the coating surface. The x-ray diffraction results of the treated coating confirm the formation of sodium aluminum hydrogen phosphate (Na3Al(OH)(HPO4)(PO4) film (SAHP). Electrochemical results obtained in artificial ocean water solution (ASTM D1141) show that treatment of the coating with 0.5 M NaH2PO4 enhanced the corrosion resistance properties for up to 7 days of exposure, but once the exposure periods are extended, the treated coatings exhibited deterioration because SAHP film started to dissolve in aggressive ions, i.e., artificial ocean water solution which makes the solution acidic owing to the formation of hydrogen phosphate and phosphoric acid. The AC sample shows protection after 60 days of exposure in artificial ocean water solution owing to the formation of protective, adherent, and uniform alpha-Al(OH)(3) as corrosion products.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Han Seung photo

Lee, Han Seung
ERICA 공학대학 (MAJOR IN ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE