Ultrasound-induced break-in method for an incoming polyvinyl acetal (PVA) brush used during post-CMP cleaning process
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Jung-Hwan | - |
dc.contributor.author | Poddar, Maneesh Kumar | - |
dc.contributor.author | Yerriboina, Nagendra Prasad | - |
dc.contributor.author | Ryu, Heon-Yul | - |
dc.contributor.author | Han, Kwang-Min | - |
dc.contributor.author | Kim, Tae-Gon | - |
dc.contributor.author | Hamada, Satomi | - |
dc.contributor.author | Wada, Yutaka | - |
dc.contributor.author | Hiyama, Hirokuni | - |
dc.contributor.author | Park, Jin-Goo | - |
dc.date.accessioned | 2021-06-22T09:42:11Z | - |
dc.date.available | 2021-06-22T09:42:11Z | - |
dc.date.issued | 2019-09 | - |
dc.identifier.issn | 0142-9418 | - |
dc.identifier.issn | 1873-2348 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/2328 | - |
dc.description.abstract | The presence of particle contamination on a wafer surface is one of the most critical issues performed by chemical mechanical planarization (CMP) and post-CMP cleaning processes. Among the various sources of contaminations, an incoming polyvinyl acetal (PVA) brush generates fine impurities in the form of particulate residue during post-CMP cleaning. This study deals with removal of this particulate residue from the incoming PVA brush via a new ultrasound-assisted physical break-in process. Strong microturbulence and shock waves generated during the ultrasound-assisted cleaning process removed the particulate residue present in the incoming PVA brush in a short cleaning time of 5 min. A detailed study involving the effects of ultrasound frequency and input power and change in dissolved gas ratio was investigated on particulate residue using a liquid particle count test. Among the variously used ultrasonic parameters, a frequency of 40 kHz and an input power of 600 W showed the highest particulate residue removal from the incoming PVA brush without damaging the brush morphology. This removal of impurities from the brush is essentially attributed to the physical effect of ultrasound and cavitation due to generation of strong microturbulence and shock waves during the PVA brush cleaning process. | - |
dc.format.extent | 6 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Elsevier BV | - |
dc.title | Ultrasound-induced break-in method for an incoming polyvinyl acetal (PVA) brush used during post-CMP cleaning process | - |
dc.type | Article | - |
dc.publisher.location | 영국 | - |
dc.identifier.doi | 10.1016/j.polymertesting.2019.105962 | - |
dc.identifier.scopusid | 2-s2.0-85068407488 | - |
dc.identifier.wosid | 000499943400030 | - |
dc.identifier.bibliographicCitation | Polymer Testing, v.78, pp 1 - 6 | - |
dc.citation.title | Polymer Testing | - |
dc.citation.volume | 78 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 6 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | sci | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalResearchArea | Polymer Science | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Characterization & Testing | - |
dc.relation.journalWebOfScienceCategory | Polymer Science | - |
dc.subject.keywordPlus | CAVITATION | - |
dc.subject.keywordPlus | FREQUENCY | - |
dc.subject.keywordPlus | BUBBLES | - |
dc.subject.keywordPlus | Morphology | - |
dc.subject.keywordPlus | Removal | - |
dc.subject.keywordPlus | Shock waves | - |
dc.subject.keywordPlus | Ultrasonics | - |
dc.subject.keywordAuthor | PVA brush | - |
dc.subject.keywordAuthor | Break-in process | - |
dc.subject.keywordAuthor | Post-CMP cleaning | - |
dc.subject.keywordAuthor | Ultrasound | - |
dc.subject.keywordAuthor | Particle contaminants | - |
dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0142941819308815?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.