Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Study on possible root causes of contamination from an incoming PVA brush during post-CMP cleaning

Authors
Lee, Jung-HwanPurushothaman, MuthukrishnanHan, Kwang-MinRyu, Heon-YulYerriboina, Nagendra PrasadKim, Tae-GonWada, YutakaHamada, SatomiHiyama, HirokuniPark, Jin-Goo
Issue Date
Aug-2019
Publisher
Elsevier BV
Keywords
PVA brush; Break-in process; Post CMP cleaning; Organic contaminants; Particulate contaminants
Citation
Polymer Testing, v.77, pp.1 - 9
Indexed
SCIE
SCOPUS
Journal Title
Polymer Testing
Volume
77
Start Page
1
End Page
9
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/2425
DOI
10.1016/j.polymertesting.2019.105921
ISSN
0142-9418
Abstract
Generation of organic defects is one of the most critical issues that encountered during post-CMP cleaning process in sub 10 nm semiconductor device fabrication. Among the many sources for producing organic defects, we found that an incoming polyvinyl acetal (PVA) brush itself acts as a vital contaminant source and is generating the organic defects during post-CMP cleaning. To find out the residual impurities of an incoming brush, we used a new break-in process to extract the brush contaminants systematically. This method has high efficiency in capturing the insoluble particulates as well as soluble contaminants from an incoming PVA brush by using ultrasonic cleaner in DIW. The insoluble particulate contaminants were extracted completely by using ultrasonication within 10 min. The analyzed particle sizes were ranged from 0.8 to 4 mu m measured by a liquid particle counter and FE-SEM. The composition of soluble impurity was investigated by various analysis methods such as ICP-MS, LC-MS and TOF-SIMS. These results emphasize that residual impurities from an incoming PVA brush might be one of the main root causes of organic residues generated during post CMP cleaning process. It was found that the incoming brush could transfer organic contaminants like PDMS (Polydimethyl siloxane) and SDS (Sodium dodecyl sulfate) to the wafers. The proposed methodology is very effective and fast process to capture and analyze the impurities from the brush.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MATERIALS SCIENCE AND CHEMICAL ENGINEERING > 1. Journal Articles
COLLEGE OF ENGINEERING SCIENCES > MAJOR IN APPLIED MATERIAL & COMPONENTS > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher KIM, TAE GON photo

KIM, TAE GON
ERICA 공학대학 (MAJOR IN APPLIED MATERIAL & COMPONENTS)
Read more

Altmetrics

Total Views & Downloads

BROWSE